Literature DB >> 26796194

Prognostic Significance of Polymer Coatings in Zotarolimus-Eluting Stents.

M Bilal Iqbal1, Imad J Nadra2, Jehangir N Din2, Cara Hendry2, Lillian Ding3, Anthony Fung4, Eve Aymong5, Albert W Chan6, Steven Hodge7, Simon D Robinson2, Anthony Della Siega2.   

Abstract

Polymer coatings on drug-eluting stents (DES) serve as a vehicle for delivery of antirestenotic drugs. Whether they influence outcomes for contemporary DES is unknown. The evolution of polymer coatings for zotarolimus-eluting stents (ZES) provides a natural experiment that facilitates such analysis. The Resolute ZES (R-ZES) uses the same antirestenotic drug as the Endeavor ZES (E-ZES) but has a more biocompatible polymer with enhanced drug release kinetics. However, there are limited data on the real-world comparative efficacy of R-ZES and the preceding E-ZES. Thus, we analyzed 17,643 patients who received either E-ZES or R-ZES from 2008 to 2014 from the British Columbia Cardiac Registry. A total of 9,869 patients (56%) received E-ZES and 7,774 patients (44%) received R-ZES. Compared with E-ZES, R-ZES was associated with lower 2-year mortality (4.1% vs 6.4%, p <0.001) and 2-year target vessel revascularization (TVR; 6.8% vs 10.7%, p <0.001). R-ZES use was an independent predictor of lower mortality rate and TVR. This was confirmed in propensity-matched analyses for 2-year mortality (hazard ratio [HR] 0.59, 95% CI 0.49 to 0.71, p <0.001) and 2-year TVR (HR 0.86, 95% CI 0.75 to 0.98, p = 0.032). Instrumental variable analyses demonstrated R-ZES to be associated with lower 2-year mortality (Δ = -2.2%, 95% CI -4.3% to -0.2%, p = 0.032) and 2-year TVR (Δ = -3.3% to 95% CI -6.1% to -0.7%, p = 0.015). Acknowledging the limitations of observational analyses, this study has shown that R-ZES was associated with lower long-term TVR and mortality. These data are reassuring for the newer R-ZES and demonstrate how polymer coatings may influence the clinical performance of DES with wider implications for future DES development and design.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26796194     DOI: 10.1016/j.amjcard.2015.11.056

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  Techniques in Vascular and Interventional Radiology Drug Delivery Technologies in the Superficial Femoral Artery.

Authors:  Akshaar Brahmbhatt; Sanjay Misra
Journal:  Tech Vasc Interv Radiol       Date:  2016-05-05

2.  Impact of diabetes on clinical outcomes after revascularization with the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent and the sirolimus-eluting Orsiro stent.

Authors:  Lars Jakobsen; Evald H Christiansen; Phillip Freeman; Johnny Kahlert; Karsten Veien; Michael Maeng; Bent Raungaard; Julia Ellert; Steen D Kristensen; Martin K Christensen; Christian J Terkelsen; Troels Thim; Ashkan Eftekhari; Rebekka V Jensen; Nicolaj B Støttrup; Anders Junker; Henrik S Hansen; Lisette O Jensen
Journal:  Catheter Cardiovasc Interv       Date:  2022-04-06       Impact factor: 2.585

3.  Comparison of the Major Clinical Outcomes for the Use of Endeavor® and Resolute Integrity® Zotarolimus-Eluting Stents During a Three-Year Follow-up.

Authors:  Yong Hoon Kim; Ae-Young Her; Seung-Woon Rha; Byoung Geol Choi; Se Yeon Choi; Jae Kyeong Byun; Yoonjee Park; Dong Oh Kang; Won Young Jang; Woohyeun Kim; Cheol Ung Choi; Chang Gyu Park; Hong Seog Seo
Journal:  Glob Heart       Date:  2020-02-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.