Rahul Gupta1, Manisha Saxena2, Rozy Paul3, Sharan Gubbi1, Praveen Mathur1.
Abstract
A blunt‑tipped red rubber catheter is used to confirm the presence of esophageal atresia in any newborn with drooling of saliva and frothing from the mouth. Failure to pass it beyond 10cms into the esophagus is considered diagnostic. We here in report an extremely rare case of broken tip of red rubber catheter lodged in the laryngopharynx of 2-day-old neonate of esophageal atresia with distal tracheoesophageal fistula. During endotracheal intubation foreign body was accidentally removed.Entities:
Keywords: Esophageal atresia; Foreign body; Laryngopharynx; Neonate; Red rubber catheter