Literature DB >> 26792927

The fate of mild-to-moderate proximal aortic dilatation after isolated aortic valve replacement for bicuspid aortic valve stenosis: a magnetic resonance imaging follow-up study†.

Evaldas Girdauskas1, Mina Rouman2, Kushtrim Disha2, Georg Dubslaff3, Beatrix Fey3, Martin Misfeld4, Kambis Mashayekhi5, Michael A Borger6, Thomas Kuntze2.   

Abstract

OBJECTIVES: The treatment of mild-to-moderate aortic dilatation at the time of aortic valve replacement (AVR) in patients with bicuspid aortic valve (BAV) disease is still controversial. We aimed to estimate late progression of aortopathy in patients who underwent isolated AVR for BAV stenosis with concomitant proximal aortic dilatation of ≥40 mm.
METHODS: The review of our institutional BAV database (n = 510) revealed a subgroup of 96 consecutive BAV patients (57 ± 10 years, 78% male) with BAV stenosis and concomitant ascending aortic dilatation of ≥40 mm [i.e. as defined by magnetic resonance imaging (MRI)/computed tomography (CT)], who underwent isolated AVR from 1995 to 2006. Aortic diameters were quantified by preoperative MRI/CT in all patients (i.e. all cases without MRI/CT were excluded). Moreover, we excluded all cases of simultaneous aortic surgery. MRI/CT follow-up (855 patient-years) was obtained in 83 (87%) patients. Study end-points were progression of proximal aortic diameters (mm/patient-year) and prevalence of aortic events (sudden death, aortic dissection and aortic surgery).
RESULTS: MRI/CT follow-up (mean 10.3 ± 3.8 years post-AVR) revealed no significant progress of maximal cross-sectional aortic diameters (i.e. 46.4 ± 4.4 mm pre-AVR vs 46.9 ± 4.6 mm post-AVR, P = 0.1). Aortic diameters were identical in 54 (65%) patients. The mean progression rate of maximal cross-sectional aortic diameter was 0.09 mm/patient-year for the whole study cohort, whereas diameter increase of ≥5 mm was revealed in 1 (1%) patient. No aortic dissection occurred. Five (5%) patients underwent redo aortic surgery for aneurysm, whereas 3 of them had aortic diameters identical to pre-AVR.
CONCLUSIONS: Mild-to-moderate ascending aortic dilatation remains stable in most BAV patients who underwent isolated AVR surgery for aortic valve stenosis at least 10-year post-AVR.
© The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic aneurysm; Aortopathy; Bicuspid aortic valve

Mesh:

Year:  2016        PMID: 26792927     DOI: 10.1093/ejcts/ezv472

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  6 in total

Review 1.  Bicuspid aortic valve related aortopathy.

Authors:  Sina Stock; Salah A Mohamed; Hans-Hinrich Sievers
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-08-30

Review 2.  Pathogenic Mechanisms of Bicuspid Aortic Valve Aortopathy.

Authors:  Noor M Yassine; Jasmine T Shahram; Simon C Body
Journal:  Front Physiol       Date:  2017-09-25       Impact factor: 4.566

3.  Differential flow improvements after valve replacements in bicuspid aortic valve disease: a cardiovascular magnetic resonance assessment.

Authors:  Malenka M Bissell; Margaret Loudon; Aaron T Hess; Victoria Stoll; Elizabeth Orchard; Stefan Neubauer; Saul G Myerson
Journal:  J Cardiovasc Magn Reson       Date:  2018-02-08       Impact factor: 5.364

Review 4.  Novel Approaches for BAV Aortopathy Prediction-Is There a Need for Cohort Studies and Biomarkers?

Authors:  Evaldas Girdauskas; Johannes Petersen; Niklas Neumann; Shiho Naito; Tatiana Gross; Annika Jagodzinski; Hermann Reichenspurner; Tanja Zeller
Journal:  Biomolecules       Date:  2018-07-19

5.  Impact of Non-Valvular Non-Coronary Concomitant Procedures on Outcomes of Surgical Aortic Valve Replacement in Intermediate Risk Patients.

Authors:  Fanar Mourad; Ali Haddad; Janine Nowak; Mohamed Elbarraki; Yacine Elhmidi; Marinela Jasarevic; Philipp Marx; Ender Demircioglu; Daniel Wendt; Matthias Thielmann; Bastian Schmack; Arjang Ruhparwar; Sharaf-Eldin Shehada
Journal:  J Clin Med       Date:  2021-11-28       Impact factor: 4.241

6.  Ascending Aorta Diameter Changes after Aortic Valve Replacement in Elderly Patients with Aortic Valve Stenosis.

Authors:  Jiamiao Gong; Kang An; Hongyuan Lin; Jianfeng Hou
Journal:  Cardiol Res Pract       Date:  2022-09-10       Impact factor: 1.990

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.