Literature DB >> 26790871

A fast method for analysing six perfluoroalkyl substances in human serum by solid-phase extraction on-line coupled to liquid chromatography tandem mass spectrometry.

Mónica Bartolomé1, Alejandrina Gallego-Picó2, Olga Huetos1, Miguel Ángel Lucena1, Argelia Castaño3.   

Abstract

We have developed and validated an on-line TurboFlow solid-phase extraction procedure coupled to high-performance liquid chromatography with tandem mass spectrometry for the analysis of six perfluoroalkyl substances (PFAS), two sulfonates (perfluorooctane sulfonate and perfluorohexane sulfonate), three carboxylates (perfluorooctanoic acid, perfluorononanoic acid and perfluorodecanoic acid), and one sulfonamide (N-methylperfluorooctane sulfonamide), in human serum samples. This method requires only 100 μL of sample and involves a short pre-treatment with acetonitrile followed by addition of a labelled internal standard for quantification and ultracentrifugation. All PFAS were detected with a run time of 8.5 min. Linearity ranges stay between 0.1 and 20 μg L(-1) (R (2) > 0.9960). Recoveries were determined by spiking blank serum samples with a mixture of six PFAS and found to be in the range 96-110 % for all compounds. Isotopic dilution was used to quantify the selected analytes. The low limits of quantification obtained, between 0.16 and 0.34 μg L(-1), small volume of sample required and short run time used (from two to three times shorter than any other described method), make this validated method highly recommended for human biomonitoring studies.

Entities:  

Keywords:  Human biomonitoring; Human serum; Liquid chromatography with tandem spectrometry; On-line solid-phase extraction; Perfluoroalkyl substances; Turbo flow extraction

Mesh:

Substances:

Year:  2016        PMID: 26790871     DOI: 10.1007/s00216-016-9319-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  Analysis of per- and polyfluorinated alkyl substances in sub-sampled water matrices with online solid phase extraction/isotope dilution tandem mass spectrometry.

Authors:  Toby Sanan; Matthew Magnuson
Journal:  J Chromatogr A       Date:  2020-06-07       Impact factor: 4.759

2.  Development and validation of a high resolving power absolute quantitative per- and polyfluoroalkyl substances method incorporating Skyline data processing.

Authors:  Jeffrey R Enders; Rebecca A Weed; Emily H Griffith; David C Muddiman
Journal:  Rapid Commun Mass Spectrom       Date:  2022-06-15       Impact factor: 2.586

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.