| Literature DB >> 26790794 |
Anna Thomas, Gopalakrishna Pemmaraju, Gurpreet Nagra, James Bassett, Shreeram Deshpande.
Abstract
Intra-osseous pin sites used in Computer Navigated knee Arthroplasty are known to cause complications including infection, neurovascular injury, thermal necrosis and peri-prosthetic fracture. Many studies have looked at ways of reducing these risks to improve results in computer-navigated surgery. We present our complication rates and techniques used to reduce complications in a retrospective study of 321 patients performed by a single surgeon in between 2009 and 2013. One patient was identified with a superficial pin site infection. No major complications were recorded during a mean follow up period of 31 months. Attention to detail in every aspect of pin insertion reduces the rates of both minor and major complications. In particular rates of peri-prosthetic fracture were shown to be lower when using a uni-cortical drilling technique compared with the use of bicortical drilling in other studies.Entities:
Mesh:
Year: 2015 PMID: 26790794
Source DB: PubMed Journal: Acta Orthop Belg ISSN: 0001-6462 Impact factor: 0.500