Literature DB >> 26780943

Magnetic field sensitivity at 7-T using dual-helmholtz transmit-only coil and 12-channel receive-only bended coil.

Kyoung-Nam Kim1, Yeunchul Ryu2,3, Jeung-Hoon Seo1, Young-Bo Kim4.   

Abstract

The purpose of this study was to combine a dual-Helmholtz (DH) transmit (Tx)-only coil and 12-channel receive (Rx)-only bended phased array (PA) coil to improve the magnetic flux (|B1 |) sensitivity in the superior-to-inferior (S-I) direction during human brain magnetic resonance imaging (MRI) at 7-T. The proposed coil combination was primarily implemented by electromagnetic (EM) simulation and compared with the 16-leg birdcage coil and 8-channel PA coil, which are generally used for the Tx- and Rx-only modes, respectively. The optimal coil combinations for the proposed structure were determined by |B1 | field calculations using the |BT+ | and |BR- | fields, which are respectively the transmit and receive components of the |B1 | field. The coil performance was then evaluated by a bench test and 7-T MRI experiment. The results of the computational calculations indicated that the |BT+ | field of the DH coil was distributed similarly to that of the 16-leg birdcage coil despite the fewer conducting legs of the former. However, the 12-channel Rx-only bended PA coil had clearly higher |BR- | profiles compared to the 8-channel PA coil. The results of the 7-T in vivo experiment showed that the proposed combination of the DH Tx-only coil and 12-channel Rx-only bended PA coil had better |B1 | field homogeneity in the sagittal slice as well as higher |B1 | field sensitivity during human brain MRI compared to an 8-channel Rx-only PA coil. SCANNING 38:515-524,
© 2015 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

Entities:  

Keywords:  MRI; bended; birdcage coil; dual-Helmholtz coil; magnetic flux; phased array coil

Year:  2016        PMID: 26780943     DOI: 10.1002/sca.21290

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  2 in total

1.  A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T.

Authors:  Jeung-Hoon Seo; Jun-Young Chung
Journal:  Sensors (Basel)       Date:  2022-02-15       Impact factor: 3.576

2.  A Comparative Study of Birdcage RF Coil Configurations for Ultra-High Field Magnetic Resonance Imaging.

Authors:  Jeung-Hoon Seo; Yeji Han; Jun-Young Chung
Journal:  Sensors (Basel)       Date:  2022-02-23       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.