Do-Hyeong Kwon1, Jai-Dong Moon1, Won-Ju Park1, Won-Yang Kang1, Soo-Hyeon Kim1, Hyeong-Min Lim1, Ji-Sung Ahn1, Hong-Jae Chae1.
Abstract
BACKGROUND: An outbreak of eye diseases occurred among workers at a poultry abattoir in South Korea from December 2012 to June 2013. An epidemiological investigation of the causative agent was conducted. The workers were given a special health examination and workplace environmental monitoring was performed. Workers with ocular symptoms subsequently underwent an ophthalmic examination. CASE PRESENTAION: From a total of 41 workers, 26 (63.4 %) were diagnosed with keratoepitheliopathy by ophthalmic examination. Environmental monitoring of the workplace revealed that the ultraviolet (UV) apron-disinfection lamp had not been turning off at the set times, and so the workers' faces had been exposed to UV radiation. Effective radiation dose measurement showed a UV-B exposure of 7-30 μW/cm(2), and a UV-C exposure of 40-200 μW/cm(2); both values exceed the occupational exposure limits. The outbreak ceased after the lamp was repaired.Entities:
Keywords: Photokeratitis; Poultry abattoir; South Korea; Ultraviolet
Year: 2016 PMID: 26779342 PMCID: PMC4714468 DOI: 10.1186/s40557-015-0087-7
Source DB: PubMed Journal: Ann Occup Environ Med ISSN: 2052-4374
General characteristics of the workers (n = 41)
| Characteristics |
|
|---|---|
| Sex | |
| Men | 13 (31.7) |
| Women | 28 (68.3) |
| Age (years) | |
| 30-39 | 7 (17.1) |
| 40-49 | 13 (31.7) |
| 50-59 | 14 (34.1) |
| 60-69 | 7 (17.1) |
| Work duration (years) | |
| 0-4 | 19 (46.3) |
| 5-9 | 13 (31.7) |
| 10≥ | 9 (22.0) |
| Process | |
| Mooring | 8 (19.5) |
| Cutting of meat | 9 (21.9) |
| Evisceration and cleaning | 10 (24.4) |
| Selection | 14 (34.2) |
Fig. 1Timeline of epidemiological investigation
Fig. 2Example of keratoepitheliopathy observed by fluorescein staining
Fig. 3Example of keratoepitheliopathy observed by slit-lamp microscopy
Symptoms and test results of the workers (n = 41)
| Symptoms and test results |
|
|---|---|
| Symptoms | |
| Ocular symptoms | 26 (63.4) |
| Skin symptoms | 4 (9.7) |
| Respiratory symptoms | 0 (0.0) |
| Keratoepitheliopathy diagnosis | 26 (63.4) |
Symptoms by work process
| Variables | n | Skin symptoms |
| Ocular symptoms |
|
|---|---|---|---|---|---|
| Mooring | 8 | 2 (25.0) | 0.112 | 3 (37.5) | 0.142 |
| Cut of meat | 9 | 5 (55.5) | 8 (88.8) | ||
| Evisceration and cleaning | 10 | 1 (10.0) | 5 (50.0) | ||
| Selection | 14 | 3 (21.4) | 10 (71.0) | ||
| Total | 41 | 11(26.8) | 26(63.4) |
*p-value was calculated using the chi-square test
Keratoepitheliopathy by work process
| Variables | N | Keratoepitheliopathy n (%) |
|
|---|---|---|---|
| Mooring | 8 | 4 (50.0) | 0.393 |
| Cut of meat | 9 | 7 (77.7) | |
| Evisceration and cleaning | 10 | 6 (60.0) | |
| Selection | 14 | 9 (64.2) | |
| Total | 41 | 26(63.4) |
* p-value was calculated using the chi- square test
Workplace environmental monitoring of chemicals by process
| Variables | Volume (L) | Measuring position | Measuring time | Measurements (ppm) | Exposure limit | Measurement Way |
|---|---|---|---|---|---|---|
| Cleaning | ||||||
| Chlorine | 320.4 | RS | 10:01 ~ 15:21 | 0.0108 | 0.5 ppm | Filtration/IC |
| Hydrochloric acid | 50.8 | RS | 11:15 ~ 15:17 | ND | 1.0 ppm | Solid/IC |
| Sodium hydroxide | 30.0 | RS | 11:17 ~ 11:32 | ND | 2.0 mg/m3 | Filtration/AA |
| Cleaning finish | ||||||
| Chlorine | 324 | RS | 10:01 ~ 15:21 | 0.0107 | 0.5 ppm | Filtration/IC |
| Hydrochloric acid | 55.9 | RS | 11:15 ~ 15:17 | ND | 1.0 ppm | Solid/IC |
| Sodium hydroxide | 30.0 | RS | 11:17 ~ 11:32 | ND | 2.0 mg/m3 | Filtration/AA |
| Evisceration | ||||||
| Hydrochloric acid | 52.0 | RS | 11:15 ~ 15:17 | ND | 1.0 ppm | Filtration/IC |
| Sodium hydroxide | 30.0 | RS | 11:17 ~ 11:32 | ND | 2.0 mg/m3 | Filtration/AA |
RS Regional samples, ND Not detected, IC Ion chromatography, AA Atomic absorption
Workplace environmental monitoring of ultraviolet C by equipment
| Variables | UVC effective radiation (μW/cm2) |
|---|---|
| First floor | |
| Screening package | 3.0 ~ 3.5 |
| Disinfection lamp | 40.0 ~ 160.0 |
| Second floor | |
| Screening package | 3.0 ~ 4.5 |
| Disinfection lamp | 40.0 ~ 200.0 |
UVC: Ultraviolet C, Screening package: Chicken package machine by size and emit ultraviolet in the workplace
Fig. 4Dysfunctional ultraviolet disinfection lamp: Since the lamps did not turn off automatically, even when the doors were opened, the faces of workers were exposed to ultraviolet radiation