Sonicating multi-lumen sliced catheter tips after the roll-plate technique improves the detection of catheter colonization in adults.

María Guembe1, Pablo Martín-Rabadán2, Raquel Cruces3, María Jesús Pérez Granda4, Emilio Bouza2.   

Abstract

The Maki technique is the standard method for detecting catheter tip (CT) colonization. However, some "multi-lumen" catheters finish in a vaulted fornix and end at different distances from the CT. Therefore, we compared the traditional Maki technique with the sonication method using several cross-cut fragments of the CT. Our objective was to assess the yield of the Maki technique followed by sonication in the detection of adult CT colonization and catheter-related bloodstream infection (C-RBSI). For 3 months, we prospectively performed CT cultures of polyurethane catheters from adult patients admitted to our institution. First, we performed CT culture using the Maki technique on blood agar plates and then sonicated small fragments of CTs in 5 ml of BHI followed by culture of 100 μl of the sonicate. We included a total of 252 CVCs, with overall colonization and C-RBSI rates of 14.3% (36/252) and 5.9% (15/252). Of the 36 colonized CVCs, 21 (58.3%) were detected both by Maki and sonication, 6 (16.7%) were detected only by Maki technique, and 9 (25.0%) only by sonication method. Among 15 episodes with concomitant bacteremia, both techniques were positive and concordant in 9 cases (60.0%), the result of the Maki was positive in only 1 (6.7%), and sonication in 5 (33.3%). Our study shows that both techniques are complementary. We recommend sonicating fragments of the CT from patients with bacteremia of unknown origin and a negative CT culture by the Maki technique.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Central venous catheter; Pre-treatment; Roll-plate technique; Slicing; Sonication

Mesh:

Substances:

Year:  2016        PMID: 26778418     DOI: 10.1016/j.mimet.2016.01.004

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  2 in total

1.  Sonication did not provide reliability to Maki technique for catheter related bloodstream infection diagnosis.

Authors:  L Lorente; M Lecuona; A Pérez-Llombet; A González-Mesa; M Callejón; T Delgado Melian; I Olaya Garcia; I Alejandro Jiménez; M L Mora; A Madueño
Journal:  Rev Esp Quimioter       Date:  2021-11-30       Impact factor: 1.553

2.  Tetrasodium EDTA Is Effective at Eradicating Biofilms Formed by Clinically Relevant Microorganisms from Patients' Central Venous Catheters.

Authors:  Fangning Liu; Satyender Hansra; Gordon Crockford; Wolfgang Köster; Brenda J Allan; Joseph M Blondeau; Chantal Lainesse; Aaron P White
Journal:  mSphere       Date:  2018-11-28       Impact factor: 4.389

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.