Literature DB >> 26776292

Accuracy evaluation of computer-designed surgical guide template in oral implantology.

Pei Shen, Jingyang Zhao, Linfeng Fan, Hanxuan Qiu, Weifeng Xu, Yanhui Wang, Shanyong Zhang, Yong-Jin Kim.   

Abstract

OBJECTIVE: The purpose of this study was to assess the accuracy of implant placement using surgical guide templates, and to compare the results with implant placement based on computer-aided design (CAD) planning merely.
MATERIAL AND METHODS: A total of 60 patients with dentition defects were included in our study, who were equally divided into group I and group II. Preoperative cone beam computed tomography (CBCT) was performed and preoperative planning was designed with Simplant software for all 60 patients. A total of 52 implants were placed in group I patients based on the preoperative planning without surgical guide templates. Implant surgical guide templates for group II patients were designed and produced by a rapid prototyping (RP) technique. A total of 57 implants were inserted in group II patients with the assistance of surgical templates. Postoperative CBCT was performed for all 60 patients. Image registration was carried out between postoperative CBCT data and that of preoperative planning data. Deviations of the implant between the actual and planned positions were measured and compared.
RESULTS: There was no significant structure damage during the surgery. Osseointegration was achieved in all implants, and both soft and hard tissues around implants were stable. Variation at the implant shoulder in group II was 1.18 ± 0.72 mm, apex 1.43 ± 0.74 mm, angulation 4.21 ± 1.91 mm, and depth 0.54 ± 0.29 mm, whereas the variation in group I was 2.07 ± 0.51 mm (P < 0.01), 2.89 ± 1.02 mm (P < 0.01), 8.84 ± 4.64 mm (P < 0.05), and 0.78 ± 0.33 mm (P > 0.05).
CONCLUSION: The use of surgical guide templates can achieve higher precision and accuracy in implant shoulder, apex, and angulation, which is much more suitable for complicated procedures and conditions such as the flapless method, immediate loading, aesthetic restoration, and insufficient bone height.

Entities:  

Mesh:

Year:  2015        PMID: 26776292     DOI: 10.1016/j.jcms.2015.10.022

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  14 in total

1.  [Precise implant insertion technology for measuring dental implant placement].

Authors:  Lu-Ming Jia; Jin-Xiu He; Jia-Yi Lu; Ping Yu; Jia Guo; Lin Fan; Chun-Xu Liu; Hai-Yang Yu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

2.  [Research advances in the use of digital surgical guides in implantology].

Authors:  Xiao-Hua Wang; Ai-Peng Liu; Wen-Zheng Deng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

3.  Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography.

Authors:  Yan-Hui Sang; Hong-Cheng Hu; Song-He Lu; Yu-Wei Wu; Wei-Ran Li; Zhi-Hui Tang
Journal:  Chin Med J (Engl)       Date:  2016-06-20       Impact factor: 2.628

4.  Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using "trapdoor" method.

Authors:  Ying Kai Hu; Qian Yang Xie; Chi Yang; Guang Zhou Xu
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

5.  Three-dimensional computer-guided implant placement in oligodontia.

Authors:  Marieke A P Filius; Joep Kraeima; Arjan Vissink; Krista I Janssen; Gerry M Raghoebar; Anita Visser
Journal:  Int J Implant Dent       Date:  2017-07-08

6.  Three-dimensional measurement of periodontal surface area for quantifying inflammatory burden.

Authors:  Sa-Beom Park; So-Youn An; Won-Jeong Han; Jong-Tae Park
Journal:  J Periodontal Implant Sci       Date:  2017-06-28       Impact factor: 2.614

7.  Computer-Assisted Design Template Guided Percutaneous Radiofrequency Thermocoagulation through Foramen Rotundum for Treatment of Isolated V2 Trigeminal Neuralgia: A Retrospective Case-Control Study.

Authors:  Ran Wang; Ying Han; Lijuan Lu
Journal:  Pain Res Manag       Date:  2019-03-03       Impact factor: 3.037

8.  Restoring Edentulous Mandible with an Implant-Retained Overdenture in a Day by Means of Flapless Surgery and Stereolithographic Surgical Guide: a Case Report.

Authors:  Ilser Turkyilmaz
Journal:  J Oral Maxillofac Res       Date:  2019-03-31

Review 9.  Genioplasty with surgical guide using 3D-printing technology: A systematic review.

Authors:  Olivier Oth; Valérie Durieux; Maria-Fernanda Orellana; Régine Glineur
Journal:  J Clin Exp Dent       Date:  2020-01-01

10.  Design and manufacturing of a patient-specific nasal implant for congenital arhinia: Case report.

Authors:  Alessandro Borghi; Federica Ruggiero; Maik Tenhagen; Silvia Schievano; Allan Ponniah; David Dunaway; Justine O'Hara; Juling Ong; Jonathan A Britto
Journal:  JPRAS Open       Date:  2019-06-12
View more