In-use Stability of Ceftaroline Fosamil in Elastomeric Home Infusion Systems and MINI-BAG Plus Containers.

Sisir Bhattacharya, Satish Parekh, Mahendra Dedhiya.   

Abstract

The objective of this study was to determine in-use stability of ceftaroline fosamil infusion solution of concentrations up to 12 mg/mL in elastomeric home infusion system prefilled with 0.9% Sodium Chloride Injection USP or 5% Dextrose Injection USP and MINI-BAG Plus Container delivery devices prefilled with 0.9% sodium chloride injection. In-use ceftaroline fosamil infusion solution (12 mg/mL) was prepared for elastomeric home infusion systems (Homepump Eclipse, Baxter Intermate, and AccuRx Elastomeric Pump) pre-filled with either 0.9% sodium chloride injection or 5% dextrose; or Baxter MINI-BAG Plus Containers pre-filled with 0.9% Sodium Chloride Injection USP (4 mg/mL to 12 mg/mL ceftaroline fosamil in final solution). The systems were stored refrigerated for 24 hours followed by up to 6 hours of storage at room temperature. Samples were analyzed at various time points for assay and degradation product by a validated stability-indicating high-performance liquid chromatography method. In-use ceftaroline fosamil infusion solution, ranging from 4-mg/mL to a maximum of 12-mg/mL concentration, in elastomeric home infusion systems prefilled with 0.9% sodium chloride injection or 5% dextrose, and MINI-BAG Plus Containers prefilled with 0.9% sodium chloride injection were chemically stable for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours at room temperature and had acceptable compatibility with material used. Ceftaroline fosamil (4 mg/mL to 12 mg/mL) maintains its potency for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours of storage at room temperature upon reconstitution in infusion solution with 0.9% sodium chloride or 5% dextrose when used in elastomeric home infusion system and MINI-BAG Plus Containers delivery devices prefilled with 0.9% sodium chloride injection.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26775451

Source DB:  PubMed          Journal:  Int J Pharm Compd        ISSN: 1092-4221


  3 in total

1.  Physicochemical stability of voriconazole in elastomeric devices.

Authors:  Harmanjeet Harmanjeet; Syed Tabish R Zaidi; Long Chiau Ming; Troy Wanandy; Rahul P Patel
Journal:  Eur J Hosp Pharm       Date:  2017-04-10

2.  Physical and chemical stability of ceftaroline in an elastomeric infusion device.

Authors:  Farah Al Madfai; Syed Tabish R Zaidi; Long Chiau Ming; Troy Wanandy; Rahul P Patel
Journal:  Eur J Hosp Pharm       Date:  2017-07-24

Review 3.  Stability of Antimicrobials in Elastomeric Pumps: A Systematic Review.

Authors:  Beatriz Fernández-Rubio; Paula Del Valle-Moreno; Laura Herrera-Hidalgo; Alicia Gutiérrez-Valencia; Rafael Luque-Márquez; Luis E López-Cortés; José María Gutiérrez-Urbón; Sonia Luque-Pardos; Aurora Fernández-Polo; María V Gil-Navarro
Journal:  Antibiotics (Basel)       Date:  2021-12-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.