Literature DB >> 26774646

Constant-variable flip angles for hyperpolarized media MRI.

He Deng1, Jianping Zhong2, Weiwei Ruan2, Xian Chen2, Xianping Sun2, Chaohui Ye2, Maili Liu2, Xin Zhou3.   

Abstract

The longitudinal magnetization of hyperpolarized media, such as hyperpolarized (129)Xe, (3)He, etc., is nonrenewable. When the MRI data acquisition begins at the k-domain center, a constant flip angle (CFA) results in an image of high signal-to-noise ratio (SNR) but sacrifices the accuracy of spatial information. On the other hand, a variable flip angle (VFA) strategy results in high accuracy but suffers from a low SNR. In this paper, we propose a novel scheme to optimize both the SNR and accuracy, called constant-variable flip angles (CVFA). The proposed scheme suggests that hyperpolarized magnetic resonance signals are firstly acquired through a train of n(∗) CFA excitation pulses, followed by a train of N-n(∗) VFA excitation pulses. We simulate and optimize the flip angle used in the CFA section, the number of CFA excitation pulses, the number of VFA excitation pulses, and the initial and final variable flip angles adopted in the VFA section. Phantom and in vivo experiments demonstrate the good performance of the CVFA designs and their ability to maintain both high SNR and spatial resolution.
Copyright © 2016 Elsevier Inc. All rights reserved.

Keywords:  Constant flip angles; Constant-variable flip angles; Hyperpolarized MRI; Variable flip angles

Year:  2016        PMID: 26774646     DOI: 10.1016/j.jmr.2015.12.022

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  3 in total

1.  Mapping and correcting hyperpolarized magnetization decay with radial keyhole imaging.

Authors:  Peter J Niedbalski; Matthew M Willmering; Scott H Robertson; Matthew S Freeman; Wolfgang Loew; Randy O Giaquinto; Christopher Ireland; Ronald G Pratt; Charles L Dumoulin; Jason C Woods; Zackary I Cleveland
Journal:  Magn Reson Med       Date:  2019-03-07       Impact factor: 4.668

2.  Fast Determination of Flip Angle and T1 in Hyperpolarized Gas MRI During a Single Breath-Hold.

Authors:  Jianping Zhong; Weiwei Ruan; Yeqing Han; Xianping Sun; Chaohui Ye; Xin Zhou
Journal:  Sci Rep       Date:  2016-05-12       Impact factor: 4.379

Review 3.  In vivo methods and applications of xenon-129 magnetic resonance.

Authors:  Helen Marshall; Neil J Stewart; Ho-Fung Chan; Madhwesha Rao; Graham Norquay; Jim M Wild
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2020-12-09       Impact factor: 9.795

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.