Literature DB >> 26774509

Allergic contact dermatitis caused by titanium screws and dental implants.

Maki Hosoki1, Keisuke Nishigawa1, Youji Miyamoto2, Go Ohe2, Yoshizo Matsuka3.   

Abstract

PATIENTS: Titanium has been considered to be a non-allergenic material. However, several studies have reported cases of metal allergy caused by titanium-containing materials. We describe a 69-year-old male for whom significant pathologic findings around dental implants had never been observed. He exhibited allergic symptoms (eczema) after orthopedic surgery. The titanium screws used in the orthopedic surgery that he underwent were removed 1 year later, but the eczema remained. After removal of dental implants, the eczema disappeared completely. DISCUSSION: Titanium is used not only for medical applications such as plastic surgery and/or dental implants, but also for paints, white pigments, photocatalysts, and various types of everyday goods. Most of the usage of titanium is in the form of titanium dioxide. This rapid expansion of titanium-containing products has increased percutaneous and permucosal exposure of titanium to the population.
CONCLUSIONS: In general, allergic risk of titanium material is smaller than that of other metal materials. However, we suggest that pre-implant patients should be asked about a history of hypersensitivity reactions to metals, and patch testing should be recommended to patients who have experienced such reactions.
Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Dental implants; Metal allergy; Orthopedic surgery; Patch testing; Titanium

Mesh:

Substances:

Year:  2016        PMID: 26774509     DOI: 10.1016/j.jpor.2015.12.004

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  19 in total

Review 1.  Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review.

Authors:  Qingge Wang; Peng Zhou; Shifeng Liu; Shokouh Attarilar; Robin Lok-Wang Ma; Yinsheng Zhong; Liqiang Wang
Journal:  Nanomaterials (Basel)       Date:  2020-06-26       Impact factor: 5.076

2.  Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study.

Authors:  Shoko Miura; Shin Kasahara; Shinobu Yamauchi; Yayoi Okuyama; Akio Izumida; Jun Aida; Hiroshi Egusa
Journal:  Clin Oral Investig       Date:  2017-06-12       Impact factor: 3.573

3.  Hypersensitivity Reaction Post Laparoscopic Cholecystectomy Due to Retained Titanium Clips.

Authors:  Fabrice Yabit; Lauren Hughes; Bertha Sylvester; Frederick Tiesenga
Journal:  Cureus       Date:  2022-06-21

Review 4.  Diagnostic tests for titanium hypersensitivity in implant dentistry: a systematic review of the literature.

Authors:  Lena Katharina Müller-Heupt; Eik Schiegnitz; Sebahat Kaya; Elisabeth Jacobi-Gresser; Peer Wolfgang Kämmerer; Bilal Al-Nawas
Journal:  Int J Implant Dent       Date:  2022-07-11

5.  Positive Material Identification testing of dental implant to correlate their compositions with allergic conditions.

Authors:  Avadhesh Kumar Chaubey; Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Oral Biol Craniofac Res       Date:  2019-05-17

6.  Achieving surface chemical and morphologic alterations on tantalum by plasma electrolytic oxidation.

Authors:  Marcelo Augusto Pinto Cardoso Goularte; Gustavo Frainer Barbosa; Nilson Cristino da Cruz; Luciana Mayumi Hirakata
Journal:  Int J Implant Dent       Date:  2016-04-16

7.  Symptoms of titanium and nickel allergic sensitization in orthodontic treatment.

Authors:  Martina Zigante; Marijana Rincic Mlinaric; Marija Kastelan; Vjera Perkovic; Magda Trinajstic Zrinski; Stjepan Spalj
Journal:  Prog Orthod       Date:  2020-07-01       Impact factor: 2.750

Review 8.  Systemic Contact Dermatitis: The Routes of Allergen Entry.

Authors:  Zhouxian Pan; Yongshi Yang; Lishan Zhang; Rui Tang; Christopher Chang; Jinlyu Sun; Xianjie Zhou; Yueping Zeng; Jing Zhang
Journal:  Clin Rev Allergy Immunol       Date:  2021-08-02       Impact factor: 8.667

9.  Metal allergy patient treated by titanium implant denture: A case report with at least 4-year follow-up.

Authors:  Huijiao Yan; Shaista Afroz; Junhel Dalanon; Nami Goto; Maki Hosoki; Yoshizo Matsuka
Journal:  Clin Case Rep       Date:  2018-08-28

10.  The accuracy and stability of the maxillary position after orthognathic surgery using a novel computer-aided surgical simulation system.

Authors:  Ju-Won Kim; Jong-Cheol Kim; Chun-Gi Jeong; Kyeong-Jun Cheon; Seoung-Won Cho; In-Young Park; Byoung-Eun Yang
Journal:  BMC Oral Health       Date:  2019-01-15       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.