Literature DB >> 26774192

The cause of brachial plexopathy in robot-assisted transaxillary thyroidectomy-A neurophysiological investigation.

Uri Alkan1, Omer Zarchi2, Naomi Rabinovics1, Yuval Nachalon1, Raphael Feinmesser1, Gideon Bachar1.   

Abstract

OBJECTIVES/HYPOTHESIS: During robot-assisted transaxillary thyroidectomy, the patient's arm is maintained in an overhead flexed position for a prolonged time, which poses a risk of postoperative brachial plexopathy. The aim of the study was to identify the causes of brachial plexopathy and to assess the benefit of intraoperative neurophysiological monitoring (IONM) in preventing positional brachial plexopathy in this setting. STUDY
DESIGN: Retrospective case series.
METHODS: The computerized database of a tertiary medical center was searched for all consecutive patients who underwent robot-assisted transaxillary thyroidectomy between 2012 and 2014. Clinical, operative, and outcome parameters were collected from the medical files. Findings were compared between patients operated with and without IONM.
RESULTS: The cohort included 30 patients, 14 operated with IONM and 16 without. Three events of impending brachial plexopathy were detected in the monitored group. The monitored group had significantly better shoulder movement (P = .003), a lower rate of hypoesthesia (P = .011), less pain (P = .001) in the early postoperative period than the nonmonitored group and higher quality of life in the early postoperative period (P = .012). The monitored group was significantly younger than the nonmonitored one (P = .02) and had a significantly larger diameter of thyroid nodule than the nonmonitored group (P = .043).
CONCLUSIONS: IONM during robot-assisted transaxillary thyroidectomy may improve short-term postoperative pain and shoulder movement and longer-term quality of life. LEVEL OF EVIDENCE: 4 Laryngoscope, 126:2187-2193, 2016.
© 2016 The American Laryngological, Rhinological and Otological Society, Inc.

Entities:  

Keywords:  Robot-assisted thyroidectomy; brachial plexus; intraoperative neurophysiological monitoring; motor evoked potentials; somatosensory evoked potentials

Mesh:

Year:  2016        PMID: 26774192     DOI: 10.1002/lary.25850

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  3 in total

1.  Robot Assisted Trans Axillary Thyroidectomy: A Subcontinent Experience.

Authors:  Ashok Kumar Gupta; Amit Kumar; Abhijeet Singh; Anand Subash
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2018-04-19

Review 2.  Robotics in otorhinolaryngology - head and neck surgery.

Authors:  George Garas; Neil Tolley
Journal:  Ann R Coll Surg Engl       Date:  2018-09       Impact factor: 1.891

3.  Postsurgical complications after robot-assisted transaxillary thyroidectomy: critical analysis of a large cohort of European patients.

Authors:  Leonardo Rossi; Valentina Buoni; Lorenzo Fregoli; Piermarco Papini; Andrea De Palma; Gabriele Materazzi
Journal:  Updates Surg       Date:  2022-03-03
  3 in total