Literature DB >> 26774088

A highly sensitive biosensor for tumor maker alpha fetoprotein based on poly(ethylene glycol) doped conducting polymer PEDOT.

Min Cui1, Zhiling Song2, Yumin Wu1, Bing Guo3, Xiaojian Fan3, Xiliang Luo4.   

Abstract

Biocompatible polymers, such as poly(ethylene glycol) (PEG), are of great significance in the development of bio-interfaces and biosensors, as they possess excellent biocompatibility and are easy for modification. A novel highly biocompatible polymer composite was synthesized herein through electrochemical polymerization of the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) and a PEG derivative, 4-arm PEG terminated with thiol groups. The electrodeposited conducting polymer composite of PEG doped PEDOT (PEDOT/PEG) exhibited flake-like nanostructure, large surface area and outstanding stability. In order to further immobilize antibodies, gold nanoparticles (AuNPs) were introduced to the PEDOT/PEG composite surface through their unique interaction with the thiol groups. AuNPs modified PEDOT/PEG provided a desirable support for the immobilization of various biomolecules such as antibodies for alpha fetoprotein (AFP), a vital tumor biomarker for liver cancer. The fabricated AFP biosensor demonstrated favorable selectivity, high sensitivity, and ultralow detection limit. Furthermore, owing to the presence of PEG polymers that are highly hydrophilic, such AuNPs/PEDOT/PEG based AFP biosensor also exhibited good anti-fouling ability, and it was capable of assaying target AFP in 10% (V/V) human serum samples, indicating highly feasible potential for clinical diagnosis.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alpha fetoprotein; Biosensor; Conducting polymer; Poly(3,4-ethylenedioxythiophene); Poly(ethylene glycol)

Mesh:

Substances:

Year:  2016        PMID: 26774088     DOI: 10.1016/j.bios.2016.01.012

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

1.  Poly(3,4-ethylenedioxythiophene) doped with engineered carbon quantum dots for enhanced amperometric detection of nitrite.

Authors:  Mingxia Jiao; Zimeng Li; Yun Li; Min Cui; Xiliang Luo
Journal:  Mikrochim Acta       Date:  2018-04-06       Impact factor: 5.833

2.  Phytic acid doped poly(3,4-ethylenedioxythiophene) modified with copper nanoparticles for enzymeless amperometric sensing of glucose.

Authors:  Lili Yang; Hao Wang; Haitao Lü; Ni Hui
Journal:  Mikrochim Acta       Date:  2019-12-17       Impact factor: 5.833

3.  Aptamer based label free thrombin assay based on the use of silver nanoparticles incorporated into self-polymerized dopamine.

Authors:  Qingjun Xu; Guixiang Wang; Mingming Zhang; Guiyun Xu; Jiehua Lin; Xiliang Luo
Journal:  Mikrochim Acta       Date:  2018-04-13       Impact factor: 5.833

4.  Cerium oxide-doped PEDOT nanocomposite for label-free electrochemical immunosensing of anti-p53 autoantibodies.

Authors:  Andrés F Cruz-Pacheco; Jennifer Quinchia; Jahir Orozco
Journal:  Mikrochim Acta       Date:  2022-05-25       Impact factor: 5.833

5.  Electrodeposited poly(3,4-ethylenedioxythiophene) doped with graphene oxide for the simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid.

Authors:  Dandan Li; Mei Liu; Yingzhuan Zhan; Qi Su; Yanmin Zhang; Dongdong Zhang
Journal:  Mikrochim Acta       Date:  2020-01-04       Impact factor: 5.833

Review 6.  Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids.

Authors:  Gaia Rocchitta; Angela Spanu; Sergio Babudieri; Gavinella Latte; Giordano Madeddu; Grazia Galleri; Susanna Nuvoli; Paola Bagella; Maria Ilaria Demartis; Vito Fiore; Roberto Manetti; Pier Andrea Serra
Journal:  Sensors (Basel)       Date:  2016-05-30       Impact factor: 3.576

Review 7.  Polymers and Plastics Modified Electrodes for Biosensors: A Review.

Authors:  Sonia Lanzalaco; Brenda G Molina
Journal:  Molecules       Date:  2020-05-24       Impact factor: 4.411

8.  Progress in research on gold nanoparticles in cancer management.

Authors:  Jingwen Peng; Xiaoqiu Liang
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

9.  A label-free immunosensor based on PHEMA/graphene oxide nanocomposite for simultaneous electrochemical determination of alpha fetoprotein.

Authors:  Ying Liang; Xiaoqing Zhao; Na Wang; Jing Wang; Hou Chen; Liangjiu Bai; Wenxiang Wang
Journal:  RSC Adv       Date:  2019-06-03       Impact factor: 4.036

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.