Literature DB >> 26773891

Trace determination of antibacterial pharmaceuticals in fishes by microwave-assisted extraction and solid-phase purification combined with dispersive liquid-liquid microextraction followed by ultra-high performance liquid chromatography-tandem mass spectrometry.

Peiting Huang1, Pan Zhao2, Xinpeng Dai2, Xiaohong Hou1, Longshan Zhao3, Ning Liang4.   

Abstract

A novel pretreatment method involving microwave-assisted extraction and solid-phase purification combined with dispersive liquid-liquid microextraction (MAE-SPP-DLLME) followed by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was established for the simultaneous determination of six antibacterial pharmaceuticals including metronidazole, tinidazole, chloramphenicol, thiamphenicol, malachite green and crystal violet. The conditions of MAE were optimized using an orthogonal design and the optimal conditions were found to be 8mL for acetonitrile, 50°C for 5min. Then, neutral alumina column was employed in the solid-phase purification. Finally, the critical parameters affecting DLLME, including selection of extraction and dispersive solvent, adjustment of pH, salt concentration, extraction time, were investigated by single factor study. Under optimum conditions, good linearities (r>0.9991) and satisfied recoveries (Recoveries>87.0%, relative standard deviation (RSD)<6.3%) were observed for all of the target analytes. The limits of detection and quantification were 4.54-101.3pgkg(-1) and 18.02-349.1pgkg(-1), respectively. Intra-day and inter-day RSDs were all lower than 3.6%. An obvious reduction in matrix effect was observed by this method compared with microwave assisted extraction followed by purification. The established method was sensitive, rapid, accurate and employable to simultaneously determine target analytes in farmed fish, river fish and marine fish.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dispersive liquid–liquid microextraction; Fish; Microwave-assisted extraction; UHPLC–MS/MS; Veterinary pharmaceuticals residues

Mesh:

Substances:

Year:  2016        PMID: 26773891     DOI: 10.1016/j.jchromb.2015.12.059

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

Review 1.  Quantitative mass spectrometry methods for pharmaceutical analysis.

Authors:  Glenn Loos; Ann Van Schepdael; Deirdre Cabooter
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

2.  Ionic liquid-based dispersive liquid-liquid microextraction combined with functionalized magnetic nanoparticle solid-phase extraction for determination of industrial dyes in water.

Authors:  Ning Liang; Xiaohong Hou; Peiting Huang; Chao Jiang; Lijuan Chen; Longshan Zhao
Journal:  Sci Rep       Date:  2017-10-23       Impact factor: 4.379

Review 3.  Microwave-Based Technique for Fast and Reliable Extraction of Organic Contaminants from Food, with a Special Focus on Hydrocarbon Contaminants.

Authors:  Sabrina Moret; Chiara Conchione; Ana Srbinovska; Paolo Lucci
Journal:  Foods       Date:  2019-10-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.