Literature DB >> 26773535

Establishment and comparison of three novel methods for the determination of the photodynamic therapy agent 2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) in human serum.

Lin Chen1, Qingqing Xiao2, Xian Zhang1, Jin Yang3.   

Abstract

2-[1-Hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) is a second-generation photosensitizer that has been applied in clinical studies of photodynamic therapy for a variety of malignant lesions. Based on the differences in selectivity and labour intensity, three novel methods - fluorescence detection coupled with high performance liquid chromatography (LC-FLD), LC-tandem mass spectrometry (LC-MS/MS) and fluorescence-based microplate reader methods - were developed for the determination of HPPH in human serum, which allowed comparison of fluorescence and MS platform for HPPH quantification. All three methods have been validated and successfully applied to support the clinical pharmacokinetic study of HPPH. The concentrations measured by LC-FLD matched those by LC-MS/MS with a correlation coefficient (r=0.994) and coefficient of determination (r(2)=0.989). Data consistency was also found between the measurements of microplate reader and LC-MS/MS with a correlation coefficient (r=0.999) and coefficient of determination (r(2)=0.998), indicating that fluorescence assay, the low cost alternative with a relatively poorer selectivity, is clearly suitable for the quantification of HPPH. Calibration curves in the methods of LC-FLD and microplate reader were linear (r˃0.998) over the concentration range from 50 to 5000 ng/mL, and linearity was obtained over the concentration range from 5 to 1000 ng/mL in the LC-MS/MS method. Compared with the other two methods, the fluorescence-based microplate reader method with proven high selectivity should be strongly recommended because of obvious advantages such as the lowest labour intensity, the lowest instrument cost, a better sensitivity than LC-FLD and the very rapid determination of large number of samples (24 samples/40 s).
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  HPPH; Human serum; LC–FLD; LC–MS/MS; Microplate reader; Pharmacokinetics

Mesh:

Substances:

Year:  2016        PMID: 26773535     DOI: 10.1016/j.jpba.2015.12.057

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Pre-clinical compartmental pharmacokinetic modeling of 2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) as a photosensitizer in rat plasma by validated HPLC method.

Authors:  Kowthavarapu Venkata Krishna; Ranendra Narayana Saha; Anu Puri; Mathias Viard; Bruce A Shapiro; Sunil Kumar Dubey
Journal:  Photochem Photobiol Sci       Date:  2019-05-15       Impact factor: 3.982

2.  Evaluation on Short-Term Therapeutic Effect of 2 Porphyrin Photosensitizer-Mediated Photodynamic Therapy for Esophageal Cancer.

Authors:  Huilong Liu; Yanfang Liu; Li Wang; Xinjian Ruan; Fei Wang; Dandan Xu; Jing Zhang; Xiaoyan Jia; Duanqi Liu
Journal:  Technol Cancer Res Treat       Date:  2019-01-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.