Literature DB >> 26772132

Potential of atmospheric pressure chemical ionization source in gas chromatography tandem mass spectrometry for the screening of urinary exogenous androgenic anabolic steroids.

M Raro1, T Portolés1, E Pitarch1, J V Sancho1, F Hernández1, L Garrostas2, J Marcos3, R Ventura3, J Segura3, O J Pozo4.   

Abstract

The atmospheric pressure chemical ionization (APCI) source for gas chromatography-mass spectrometry analysis has been evaluated for the screening of 16 exogenous androgenic anabolic steroids (AAS) in urine. The sample treatment is based on the strategy currently applied in doping control laboratories i.e. enzymatic hydrolysis, liquid-liquid extraction (LLE) and derivatization to form the trimethylsilyl ether-trimethylsilyl enol ether (TMS) derivatives. These TMS derivatives are then analyzed by gas chromatography tandem mass spectrometry using a triple quadrupole instrument (GC-QqQ MS/MS) under selected reaction monitoring (SRM) mode. The APCI promotes soft ionization with very little fragmentation resulting, in most cases, in abundant [M + H](+) or [M + H-2TMSOH](+) ions, which can be chosen as precursor ions for the SRM transitions, improving in this way the selectivity and sensitivity of the method. Specificity of the transitions is also of great relevance, as the presence of endogenous compounds can affect the measurements when using the most abundant ions. The method has been qualitatively validated by spiking six different urine samples at two concentration levels each. Precision was generally satisfactory with RSD values below 25 and 15% at the low and high concentration level, respectively. Most the limits of detection (LOD) were below 0.5 ng mL(-1). Validation results were compared with the commonly used method based on the electron ionization (EI) source. EI analysis was found to be slightly more repeatable whereas lower LODs were found for APCI. In addition, the applicability of the developed method has been tested in samples collected after the administration of 4-chloromethandienone. The highest sensitivity of the APCI method for this compound, allowed to increase the period in which its administration can be detected.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anabolic androgenic steroids (AAS); Atmospheric pressure chemical ionization (APCI); Doping control analysis; Gas chromatography (GC); Tandem mass spectrometry (MS/MS); Triple quadrupole (QqQ)

Mesh:

Substances:

Year:  2015        PMID: 26772132     DOI: 10.1016/j.aca.2015.11.041

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

Review 1.  Quantitative mass spectrometry methods for pharmaceutical analysis.

Authors:  Glenn Loos; Ann Van Schepdael; Deirdre Cabooter
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

2.  Analysis of Grape Volatiles Using Atmospheric Pressure Ionization Gas Chromatography Mass Spectrometry-Based Metabolomics.

Authors:  Manoj Ghaste; Fulvio Mattivi; Giuseppe Astarita; Vladimir Shulaev
Journal:  Methods Mol Biol       Date:  2022

3.  Non-linear and non-additive associations between the pregnancy metabolome and birthweight.

Authors:  E Colicino; F Ferrari; W Cowell; M M Niedzwiecki; N Foppa Pedretti; A Joshi; R O Wright; R J Wright
Journal:  Environ Int       Date:  2021-07-10       Impact factor: 13.352

4.  Serum Steroid Ratio Profiles in Prostate Cancer: A New Diagnostic Tool Toward a Personalized Medicine Approach.

Authors:  Adriana Albini; Antonino Bruno; Barbara Bassani; Gioacchino D'Ambrosio; Giuseppe Pelosi; Paolo Consonni; Laura Castellani; Matteo Conti; Simone Cristoni; Douglas M Noonan
Journal:  Front Endocrinol (Lausanne)       Date:  2018-04-05       Impact factor: 5.555

Review 5.  GC/MS in Recent Years Has Defined the Normal and Clinically Disordered Steroidome: Will It Soon Be Surpassed by LC/Tandem MS in This Role?

Authors:  Cedric Shackleton; Oscar J Pozo; Josep Marcos
Journal:  J Endocr Soc       Date:  2018-07-09

6.  Dried Urine Microsampling Coupled to Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) for the Analysis of Unconjugated Anabolic Androgenic Steroids.

Authors:  Michele Protti; Camilla Marasca; Marco Cirrincione; Angelo E Sberna; Roberto Mandrioli; Laura Mercolini
Journal:  Molecules       Date:  2020-07-14       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.