| Literature DB >> 26771526 |
Hung-Hsin Liu1, Chang-Yuh Chen2, Cheng-Hang Lan3, Cheng-Ping Chang4, Chiung-Yu Peng5,6.
Abstract
This study aimed to evaluate the efficacy of powered air-purifying respirators (PAPRs) worn by the workers, and to investigate the effect of this application on exposure and preclinical effects in terms of workplace measuring and biomarker monitoring in ITO sputter target manufacturing plants and workers, respectively. Fifty-four workers were recruited and investigated from 2010-2012, during which PAPRs were provided to on-site workers in September 2011. Each worker completed questionnaires and provided blood and urine samples for analysis of biomarkers of indium exposure and preclinical effects. Area and personal indium air samples were randomly collected from selected worksites and from participants. The penetration percentage of the respirator (concentration inside respirator divided by concentration outside respirator) was 6.6%. Some biomarkers, such as S-In, SOD, GPx, GST, MDA, and TMOM, reflected the decrease in exposure and showed lower levels, after implementation of PAPRs. This study is the first to investigate the efficacy of PAPRs for reducing indium exposure. The measurement results clearly showed that the implementation of PAPRs reduces levels of indium-related biomarkers. These findings have practical applications for minimizing occupational exposure to indium and for managing the health of workers exposed to indium.Entities:
Keywords: Glutathione S-transferase; malondialdehyde; powered air-purifying respirator; serum indium
Mesh:
Substances:
Year: 2016 PMID: 26771526 DOI: 10.1080/15459624.2015.1125487
Source DB: PubMed Journal: J Occup Environ Hyg ISSN: 1545-9624 Impact factor: 2.155