Literature DB >> 26769474

A bioluminescent arsenite biosensor designed for inline water analyzer.

Sandra Prévéral1,2,3, Catherine Brutesco1,2,3, Elodie C T Descamps1,2,3, Camille Escoffier1,2,3, David Pignol1,2,3, Nicolas Ginet4,5,6, Daniel Garcia1,2,3.   

Abstract

Whole-cell biosensors based on the reporter gene system can offer rapid detection of trace levels of organic or metallic compounds in water. They are well characterized in laboratory conditions, but their transfer into technological devices for the surveillance of water networks remains at a conceptual level. The development of a semi-autonomous inline water analyzer stumbles across the conservation of the bacterial biosensors over a period of time compatible with the autonomy requested by the end-user while maintaining a satisfactory sensitivity, specificity, and time response. We focused here on assessing the effect of lyophilization on two biosensors based on the reporter gene system and hosted in Escherichia coli. The reporter gene used here is the entire bacterial luciferase lux operon (luxCDABE) for an autonomous bioluminescence emission without the need to add any substrate. In the cell-survival biosensor that is used to determine the overall fitness of the bacteria when mixed with the water sample, lux expression is driven by a constitutive E. coli promoter PrpoD. In the arsenite biosensor, the arsenite-inducible promoter P ars involved in arsenite resistance in E. coli controls lux expression. Evaluation of the shelf life of these lyophilized biosensors kept at 4 °C over a year evidenced that about 40 % of the lyophilized cells can be revived in such storage conditions. The performances of the lyophilized biosensor after 7 months in storage are maintained, with a detection limit of 0.2 μM arsenite for a response in about an hour with good reproducibility. These results pave the way to the use in tandem of both biosensors (one for general toxicity and one for arsenite contamination) as consumables of an autonomous analyzer in the field.

Entities:  

Keywords:  Bioluminescence; Biosensors; Lyophilization

Mesh:

Substances:

Year:  2016        PMID: 26769474     DOI: 10.1007/s11356-015-6000-7

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  7 in total

1.  Semi-autonomous inline water analyzer: design of a common light detector for bacterial, phage, and immunological biosensors.

Authors:  Elodie C T Descamps; Damien Meunier; Catherine Brutesco; Sandra Prévéral; Nathalie Franche; Ingrid Bazin; Bertrand Miclot; Philippe Larosa; Camille Escoffier; Jean-Raphael Fantino; Daniel Garcia; Mireille Ansaldi; Agnès Rodrigue; David Pignol; Pierre Cholat; Nicolas Ginet
Journal:  Environ Sci Pollut Res Int       Date:  2016-11-12       Impact factor: 4.223

2.  A Sensitive Magnetic Arsenite-Specific Biosensor Hosted in Magnetotactic Bacteria.

Authors:  Anissa Dieudonné; Sandra Prévéral; David Pignol
Journal:  Appl Environ Microbiol       Date:  2020-07-02       Impact factor: 4.792

3.  Immobilization of fluorescent bacterial bioreporter for arsenic detection.

Authors:  Evrim Elcin; Huseyin Avni Öktem
Journal:  J Environ Health Sci Eng       Date:  2020-01-18

Review 4.  Microbial whole-cell biosensors: Current applications, challenges, and future perspectives.

Authors:  Michael Moraskie; Md Harun Or Roshid; Gregory O'Connor; Emre Dikici; Jean-Marc Zingg; Sapna Deo; Sylvia Daunert
Journal:  Biosens Bioelectron       Date:  2021-05-23       Impact factor: 10.618

Review 5.  The Application of Whole Cell-Based Biosensors for Use in Environmental Analysis and in Medical Diagnostics.

Authors:  Qingyuan Gui; Tom Lawson; Suyan Shan; Lu Yan; Yong Liu
Journal:  Sensors (Basel)       Date:  2017-07-13       Impact factor: 3.576

6.  Characterization of a promiscuous cadmium and arsenic resistance mechanism in Thermus thermophilus HB27 and potential application of a novel bioreporter system.

Authors:  Immacolata Antonucci; Giovanni Gallo; Danila Limauro; Patrizia Contursi; Ana Luisa Ribeiro; Alba Blesa; José Berenguer; Simonetta Bartolucci; Gabriella Fiorentino
Journal:  Microb Cell Fact       Date:  2018-05-18       Impact factor: 5.328

Review 7.  Detection of contaminants in water supply: A review on state-of-the-art monitoring technologies and their applications.

Authors:  Syahidah Nurani Zulkifli; Herlina Abdul Rahim; Woei-Jye Lau
Journal:  Sens Actuators B Chem       Date:  2017-09-18       Impact factor: 7.460

  7 in total