Literature DB >> 26757420

Goose-neck snare-assisted transcatheter ASD closure: A safety procedure for large and complex ASDs.

Gianfranco Butera1, Nicusor Lovin1,2, Domenica Paola Basile1, Mario Carminati1.   

Abstract

OBJECTIVE: To report on a new technique that increases the safety of percutaneous atrial septal defect (ASD) closure using a goose-neck snare system.
BACKGROUND: ASD transcatheter closure is a widespread procedure. However, in some cases, ASDs may be large and with soft rims. In these situation, a potential risk exists for device malposition or embolization.
METHODS: When transesophageal echocardiography (TEE) evaluation and balloon sizing showed large defects with floppy rims the chosen Amplatzer device was implanted in a standard way. In large defects with floppy rims, before release a 5-mm goose-neck snare with its 4 Fr catheter was placed across the delivery cable and fixed to catch the screwing mechanism of implanted Amplatzer device. The delivery cable was unscrewed and the device reached its final position without any tension. If the position was considered satisfactory the device was released from the goose-neck snare.
RESULTS: Thirteen patients had a snare-assisted ASD transcatheter closure. Median device size was 24 mm (range 14-38 mm). Retrieval or repositioning of the device using the goose-neck snare was performed in four cases: in three patients, because of device malposition after delivery cable release and in one patient, because of unsuitability of closure of a second significant defect. Furthermore, in two subjects with multiple ASDs, a second fenestration looked quite significant with the device still attached to the delivery cable while it appeared smaller after release.
CONCLUSIONS: Snare-assisted Amplatzer ASD device placement is a new method for ASD percutaneous closure and adds safety to the procedure.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  Atrial septal defect; closure; complication; transcatheter

Mesh:

Year:  2016        PMID: 26757420     DOI: 10.1002/ccd.26369

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

1.  Tough, but not impossible - Retrieval of large atrial septal occluder devices embolized to left atrium.

Authors:  Rangaraj Ramalingam; Shivanand Patil; Natraj Setty; Jayashree Kharge; Beeresha Puttegowda; Jayasheelan Mambally Rachaiah; Cholenahally Nanjappa Manjunath
Journal:  Interv Med Appl Sci       Date:  2017-03

2.  Percutaneous closure of an aortopulmonary window in a young adult patient: a case report of transcatheter closure with an occluder device.

Authors:  Mario Giordano; Gianfranco Butera
Journal:  Eur Heart J Case Rep       Date:  2020-04-04

3.  Spectrum of morphological abnormalities and treatment outcomes in ostium secundum type of atrial septal defects: Single center experience in >500 cases.

Authors:  Ajith Ananthakrishna Pillai; Shabnasri Sinouvassalou; Kabilan S Jagadessan; Hemachandren Munuswamy
Journal:  J Saudi Heart Assoc       Date:  2018-10-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.