Literature DB >> 26757336

The Effect of Compressive Cyclic Loading on the Retention of Cast Single Crowns Cemented to Implant Abutments.

Angel Alvarez-Arenal, Ignacio Gonzalez-Gonzalez, Javier Pinés-Hueso, Hector deLlanos-Lanchares, Jaime del Rio Highsmith.   

Abstract

PURPOSE: The aim of this study was to evaluate and compare the retention strength of three cements commonly used in implant-supported prostheses before and after compressive cyclic loading.
MATERIALS AND METHODS: The working model consisted of five solid abutments, 7 mm in height and with a 6-degree taper, screw retained to five implant analogs secured in a rectangular block of self-curing acrylic. On the abutments, 30 metal Cr-Ni alloy copings were cemented using three luting agents: glass ionomer, resin urethane-based, and compomer cement (n = 10). Two tensile tests were conducted with a universal testing machine, before and after 100,000 cycles of 100 N and 0.72 Hz compressive cyclic loading in a humid environment.
RESULTS: Before applying the compressive load, the retention strength of the resin urethane-based cement was slightly higher than that of the compomer cement and 75% greater than the glass-ionomer cement. After compressive loading, the resin urethane-based cement showed the highest percentage of loss of retention (64.45%, compared with 50% for glass-ionomer and compomer cement). However, the glass-ionomer cement showed the lowest mean retentive strength with 50.35 N as opposed to 75.12 N for the compomer cement and 71.25 N for the resin urethane-based.
CONCLUSIONS: Compressive cyclic loading significantly influences the retention strength of the luting agents tested. All three cements may favor the retrievability of the crowns.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26757336     DOI: 10.11607/ijp.4355

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  3 in total

1.  Biologically oriented preparation technique (BOPT) for implant-supported fixed prostheses.

Authors:  Mª Fernanda Solá-Ruiz; Jaime Del Rio Highsmith; Carlos Labaig-Rueda; Rubén Agustín-Panadero
Journal:  J Clin Exp Dent       Date:  2017-04-01

2.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20

3.  Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study.

Authors:  Jae-Won Choi; Kyung-Hee Choi; Hee-Jin Chae; Sung-Ki Chae; Eun-Bin Bae; Jin-Ju Lee; So-Hyoun Lee; Chang-Mo Jeong; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2018-04-06       Impact factor: 3.623

  3 in total