Munawwar Ahmed1, Shyamkumar N Keshava1, Vinu Moses1, Suraj Mammen1, Korula Mani Jacob2, Vrisha Madhuri2.
Abstract
Radiofrequency ablation (RFA) has now become a preferred treatment option for osteoid osteoma. Accurate placement of RFA probe into the nidus of osteoid osteoma is important for good clinical outcome. Various methods and techniques have been described in the literature available. We describe the technique of using a vascular access sheath for introduction of RFA probe after bone drilling, which prevents loss of access to drill track and also serves as a pathway for accurate placement of RFA probe, thereby reducing the risk of damage to the RFA probe tip itself and the surrounding soft tissue.Entities:
Keywords: Computed tomography scan; osteoid osteoma; radiofrequency ablation
Year: 2015 PMID: 26752816 PMCID: PMC4693384 DOI: 10.4103/0971-3026.169460
Source DB: PubMed Journal: Indian J Radiol Imaging ISSN: 0970-2016