Literature DB >> 26752501

Initial Experiments with the Leap Motion as a User Interface in Robotic Endonasal Surgery.

T A Travaglini1, P J Swaney1, Kyle D Weaver2, R J Webster1.   

Abstract

The Leap Motion controller is a low-cost, optically-based hand tracking system that has recently been introduced on the consumer market. Prior studies have investigated its precision and accuracy, toward evaluating its usefulness as a surgical robot master interface. Yet due to the diversity of potential slave robots and surgical procedures, as well as the dynamic nature of surgery, it is challenging to make general conclusions from published accuracy and precision data. Thus, our goal in this paper is to explore the use of the Leap in the specific scenario of endonasal pituitary surgery. We use it to control a concentric tube continuum robot in a phantom study, and compare user performance using the Leap to previously published results using the Phantom Omni. We find that the users were able to achieve nearly identical average resection percentage and overall surgical duration with the Leap.

Entities:  

Keywords:  Concentric Tube Robot; Continuum Robot; Endonasal Surgery; Surgical Robot; Teleoperation; User Interface

Year:  2015        PMID: 26752501      PMCID: PMC4703412          DOI: 10.1007/978-3-319-22368-1_17

Source DB:  PubMed          Journal:  Robot Mechatron (2015)


  13 in total

1.  Adaptation of a hexapod-based robotic system for extended endoscope-assisted transsphenoidal skull base surgery.

Authors:  Ch Nimsky; J Rachinger; H Iro; R Fahlbusch
Journal:  Minim Invasive Neurosurg       Date:  2004-02

Review 2.  A review of medical robotics for minimally invasive soft tissue surgery.

Authors:  G Dogangil; B L Davies; F Rodriguez y Baena
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

3.  A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots.

Authors:  D Caleb Rucker; Bryan A Jones; Robert J Webster
Journal:  IEEE Trans Robot       Date:  2010       Impact factor: 5.567

4.  Debulking from within: a robotic steerable cannula for intracerebral hemorrhage evacuation.

Authors:  Jessica Burgner; Philip J Swaney; Ray A Lathrop; Kyle D Weaver; Robert J Webster
Journal:  IEEE Trans Biomed Eng       Date:  2013-04-30       Impact factor: 4.538

5.  Design and Control of Concentric-Tube Robots.

Authors:  Pierre E Dupont; Jesse Lock; Brandon Itkowitz; Evan Butler
Journal:  IEEE Trans Robot       Date:  2010-04-01       Impact factor: 5.567

6.  Forces Applied at the Skull Base during Transnasal Endoscopic Transsphenoidal Pituitary Tumor Excision.

Authors:  James R Bekeny; Philip J Swaney; Robert J Webster; Paul T Russell; Kyle D Weaver
Journal:  J Neurol Surg B Skull Base       Date:  2013-05-09

7.  A Telerobotic System for Transnasal Surgery.

Authors:  Jessica Burgner; D Caleb Rucker; Hunter B Gilbert; Philip J Swaney; Paul T Russell; Kyle D Weaver; Robert J Webster
Journal:  IEEE ASME Trans Mechatron       Date:  2013-06-19       Impact factor: 5.303

8.  An analysis of the precision and reliability of the leap motion sensor and its suitability for static and dynamic tracking.

Authors:  Jože Guna; Grega Jakus; Matevž Pogačnik; Sašo Tomažič; Jaka Sodnik
Journal:  Sensors (Basel)       Date:  2014-02-21       Impact factor: 3.576

9.  Analysis of the accuracy and robustness of the leap motion controller.

Authors:  Frank Weichert; Daniel Bachmann; Bartholomäus Rudak; Denis Fisseler
Journal:  Sensors (Basel)       Date:  2013-05-14       Impact factor: 3.576

Review 10.  Systematic review of Kinect applications in elderly care and stroke rehabilitation.

Authors:  David Webster; Ozkan Celik
Journal:  J Neuroeng Rehabil       Date:  2014-07-03       Impact factor: 4.262

View more
  3 in total

1.  Evaluation of contactless human-machine interface for robotic surgical training.

Authors:  Fabien Despinoy; Nabil Zemiti; Germain Forestier; Alonso Sánchez; Pierre Jannin; Philippe Poignet
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-09-15       Impact factor: 2.924

Review 2.  Review of Three-Dimensional Human-Computer Interaction with Focus on the Leap Motion Controller.

Authors:  Daniel Bachmann; Frank Weichert; Gerhard Rinkenauer
Journal:  Sensors (Basel)       Date:  2018-07-07       Impact factor: 3.576

3.  Use of Commercial Off-The-Shelf Devices for the Detection of Manual Gestures in Surgery: Systematic Literature Review.

Authors:  Fernando Alvarez-Lopez; Marcelo Fabián Maina; Francesc Saigí-Rubió
Journal:  J Med Internet Res       Date:  2019-04-14       Impact factor: 5.428

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.