High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy.

Mark W Tate1, Prafull Purohit1, Darol Chamberlain2, Kayla X Nguyen3, Robert Hovden3, Celesta S Chang4, Pratiti Deb4, Emrah Turgut3, John T Heron4, Darrell G Schlom5, Daniel C Ralph1, Gregory D Fuchs3, Katherine S Shanks1, Hugh T Philipp1, David A Muller3, Sol M Gruner1.   

Abstract

We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80-200 keV electron beams.

Entities:  

Keywords:  STEM; electron microscope pixel array detector (EMPAD); high dynamic range; mixed-mode pixel array detector (MM-PAD); pixel array detector (PAD)

Mesh:

Year:  2016        PMID: 26750260     DOI: 10.1017/S1431927615015664

Source DB:  PubMed          Journal:  Microsc Microanal        ISSN: 1431-9276            Impact factor:   4.127


  20 in total

1.  A symmetry-derived mechanism for atomic resolution imaging.

Authors:  Matus Krajnak; Joanne Etheridge
Journal:  Proc Natl Acad Sci U S A       Date:  2020-10-22       Impact factor: 11.205

2.  Automatic parameter selection for electron ptychography via Bayesian optimization.

Authors:  Michael C Cao; Zhen Chen; Yi Jiang; Yimo Han
Journal:  Sci Rep       Date:  2022-07-19       Impact factor: 4.996

3.  Orientation mapping of graphene using 4D STEM-in-SEM.

Authors:  Benjamin W Caplins; Jason D Holm; Ryan M White; Robert R Keller
Journal:  Ultramicroscopy       Date:  2020-10-13       Impact factor: 2.689

4.  Materials characterisation by angle-resolved scanning transmission electron microscopy.

Authors:  Knut Müller-Caspary; Oliver Oppermann; Tim Grieb; Florian F Krause; Andreas Rosenauer; Marco Schowalter; Thorsten Mehrtens; Andreas Beyer; Kerstin Volz; Pavel Potapov
Journal:  Sci Rep       Date:  2016-11-16       Impact factor: 4.379

5.  Direct Detection Electron Energy-Loss Spectroscopy: A Method to Push the Limits of Resolution and Sensitivity.

Authors:  James L Hart; Andrew C Lang; Asher C Leff; Paolo Longo; Colin Trevor; Ray D Twesten; Mitra L Taheri
Journal:  Sci Rep       Date:  2017-08-15       Impact factor: 4.379

6.  A fast image simulation algorithm for scanning transmission electron microscopy.

Authors:  Colin Ophus
Journal:  Adv Struct Chem Imaging       Date:  2017-05-10

7.  Electric field imaging of single atoms.

Authors:  Naoya Shibata; Takehito Seki; Gabriel Sánchez-Santolino; Scott D Findlay; Yuji Kohno; Takao Matsumoto; Ryo Ishikawa; Yuichi Ikuhara
Journal:  Nat Commun       Date:  2017-05-30       Impact factor: 14.919

8.  Atomic Resolution Defocused Electron Ptychography at Low Dose with a Fast, Direct Electron Detector.

Authors:  Jiamei Song; Christopher S Allen; Si Gao; Chen Huang; Hidetaka Sawada; Xiaoqing Pan; Jamie Warner; Peng Wang; Angus I Kirkland
Journal:  Sci Rep       Date:  2019-03-08       Impact factor: 4.379

9.  Low-dose cryo electron ptychography via non-convex Bayesian optimization.

Authors:  Philipp Michael Pelz; Wen Xuan Qiu; Robert Bücker; Günther Kassier; R J Dwayne Miller
Journal:  Sci Rep       Date:  2017-08-29       Impact factor: 4.379

10.  Electron crystallography with the EIGER detector.

Authors:  Gemma Tinti; Erik Fröjdh; Eric van Genderen; Tim Gruene; Bernd Schmitt; D A Matthijs de Winter; Bert M Weckhuysen; Jan Pieter Abrahams
Journal:  IUCrJ       Date:  2018-02-14       Impact factor: 4.769

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.