Literature DB >> 26749531

CT angiography of the aorta using 80 kVp in combination with sinogram-affirmed iterative reconstruction and automated tube current modulation: Effects on image quality and radiation dose.

Johannes Boos1, Joel Aissa1, Rotem S Lanzman1, Philipp Heusch1, Lars Schimmöller1, Christoph Schleich1, Christoph Thomas1, Gerald Antoch1, Patric Kröpil1.   

Abstract

INTRODUCTION: The objective of this study was to evaluate image quality and radiation dose of a CT angiography (CTA) protocol using 80 kVp in combination with iterative reconstruction and automated tube current modulation.
METHODS: Ninety-five aortic CTA examinations were included in this study. A novel 80 kVp aortic CTA-protocol with iterative reconstruction was introduced in our department in March 2012 for patients with a body mass index (BMI) below 32 kg/m(2). The first 72 consecutive examinations were retrospectively assigned to group A (56 patients, 42 men, 14 women, mean age 69.6 ± 10.7 years, BMI range 19.7-31.1 kg/m(2)). For comparison, the last 23 consecutive examinations performed with the old protocol (100 kVp) were assigned to group B (21 patients, 13 men, 8 women, mean age 67.4 ± 11.1 years, BMI range 19.7-31.9 kg/m(2)). Thoracic and abdominal contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and aortic attenuation were assessed. Subjective image quality was rated on a 5-point scale (1 = non diagnostic; 5 = excellent). Furthermore, dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were analysed.
RESULTS: All examinations achieved diagnostic image quality. Attenuation of the aorta was significantly higher in group A compared with B (thoracic: 443.5 ± 90.5 Hounsfield units (HU) vs. 296.0 ± 61.0 HU; abdominal: 426.3 ± 94.2 HU vs. 283.6 ± 60.5 HU; P < 0.05, respectively). CNR, SNR and subjective image quality were comparable between both groups (CNR: 12.8 ± 3.7 vs. 13.0 ± 7.4; SNR 14.4 ± 3.9 vs. 14.9 ± 8.2; subjective image quality: 4.3 ± 0.6 vs. 4.5 ± 0.6; P > 0.05, respectively). CTDIvol and DLP were significantly lower in group A (1.9 ± 0.5 mGy; 139.2 ± 41.1 mGy × cm) as compared with group B (4.2 ± 1.4 mGy; 292.1 ± 91.5 mGy × cm; P < 0.001, respectively).
CONCLUSION: Low-dose CTA of the aorta using 80 kVp with iterative reconstruction enables a significant dose reduction of up to 50% compared with a 100 kVp protocol in patients with a BMI below 32 kg/m(2) while diagnostic image quality is maintained.
© 2016 The Royal Australian and New Zealand College of Radiologists.

Entities:  

Keywords:  aorta; computed tomography; diagnostic imaging; radiation dose; vascular

Mesh:

Year:  2016        PMID: 26749531     DOI: 10.1111/1754-9485.12425

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  1 in total

1.  Determine Cumulative Radiation Dose and Lifetime Cancer Risk in Marfan Syndrome Patients Who Underwent Computed Tomography Angiography of the Aorta in Northeast Thailand: A 5-Year Retrospective Cohort Study.

Authors:  Narumol Chaosuwannakit; Phatraporn Aupongkaroon; Pattarapong Makarawate
Journal:  Tomography       Date:  2022-01-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.