Literature DB >> 26747514

Time-elapsed screw insertion with microCT imaging.

M K Ryan1, A A Mohtar2, T M Cleek2, K J Reynolds2.   

Abstract

Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Keywords:  Cancellous bone; Insertion torque; Screw insertion; Time-elapsed

Mesh:

Year:  2015        PMID: 26747514     DOI: 10.1016/j.jbiomech.2015.12.021

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Heterogeneous Strain Distribution in the Subchondral Bone of Human Osteoarthritic Femoral Heads, Measured with Digital Volume Correlation.

Authors:  Melissa K Ryan; Sara Oliviero; Maria Cristiana Costa; J Mark Wilkinson; Enrico Dall'Ara
Journal:  Materials (Basel)       Date:  2020-10-16       Impact factor: 3.623

2.  Mechanical Effects of Lag Screw Retightening in a Simulated Hindfoot Arthrodesis Model.

Authors:  Amanda L Rugg; Melissa R Requist; Brooks W Johnson; Michelle M Son; Alicia Alvarez; L Daniel Latt
Journal:  Foot Ankle Orthop       Date:  2021-06-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.