Literature DB >> 26746089

Stapled orthotopic ileal neobladder after radical cystectomy for bladder cancer: Functional results and complications over a 20-year period.

G Muto1, D Collura1, G Simone1, G L Muto2, R Rosso1, A Giacobbe1, E Castelli3.   

Abstract

AIMS: To present the long term-results and complications of a large series of stapled ileal orthotopic neobladders.
MATERIALS AND METHODS: From 1992 to 2012 we performed 606 radical cystectomies with stapled orthotopic neobladder substitution in male patients. The median patient age was 65 years (interquartile range [IQR]: 58-71).
RESULTS: Median operative time was 205 min (IQR: 180-225). The overall survival rates at 5, 10, 15, and 20 yr were 68% (336 of 494), 55% (207 of 376), 38% (98 of 259), and 23% (14 of 62), respectively, and the disease specific survival rates were 75% (371 of 494), 59% (222 of 376), 50% (130 of 259), and 35% (22 of 62), respectively. After a median follow-up of 81 months (IQR: 30-144), a total of 147 early (less than 90 days) complications (38 diversion related, 109 diversion unrelated) occurred in 144 patients (24%); 163 late complications (141 diversion related, 22 diversion unrelated) affected 141 patients (23%). At 60 months, daytime and nighttime continence was complete in 96% and 72% of cases, respectively. Urodynamic studies showed that maximum capacity, residual volume, maximum flow rate, pressure at maximum capacity, and maximum outlet closure pressure were not statistically different at 12 and 60 months postoperatively.
CONCLUSIONS: The use of a stapler when performing orthotopic neobladders significantly reduces the operating time, and offers good functional results with acceptable complication rates. Our results could encourage the use of a stapler when performing an ileal neobladder during laparoscopic and robotic radical cystectomies.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Complications; Cystectomy; Neobladder; Surgical stapler

Mesh:

Year:  2015        PMID: 26746089     DOI: 10.1016/j.ejso.2015.11.010

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  4 in total

1.  Development of bioabsorbable zinc-magnesium alloy wire and validation of its application to urinary tract surgeries.

Authors:  Yasuyoshi Okamura; Nobuyuki Hinata; Taichi Hoshiba; Tatsuya Nakatsuji; Naoko Ikeo; Junya Furukawa; Kenichi Harada; Yuzo Nakano; Takumi Fukumoto; Toshiji Mukai; Masato Fujisawa
Journal:  World J Urol       Date:  2020-02-28       Impact factor: 4.226

2.  Cutting complications before cutting corners: the need for long-term outcome parameters in an ever-changing landscape of intracorporeal neobladder technique.

Authors:  Rajesh Nair; Nicolas Geurts; Declan G Murphy
Journal:  Transl Androl Urol       Date:  2017-12

3.  Laparoscopic radical cystectomy with pelvic lymph node dissection and ileal orthotopic neobladder by a total extraperitoneal approach: Our initial technique and short-term outcomes.

Authors:  Guanqun Zhu; Zongliang Zhang; Kai Zhao; Xinbao Yin; Yulian Zhang; Zhenlin Wang; Chen Li; Yuanming Sui; Xueyu Li; Han Yang; Nianzeng Xing; Ke Wang
Journal:  Investig Clin Urol       Date:  2022-09

4.  Comparison of open and intracorporeal modified ureterosigmoidostomy (Mainz II) after laparoscopic radical cystectomy with bladder cancer.

Authors:  Duo Zheng; Junyao Liu; Gongjin Wu; Shujun Yang; Chuang Luo; Tianci Du; Yao Luo; Junsheng Bao; Junqiang Tian; Zhiping Wang; Panfeng Shang; Zhongjin Yue
Journal:  World J Surg Oncol       Date:  2021-02-20       Impact factor: 2.754

  4 in total