Literature DB >> 26746041

Polypropylene mesh augmentation for complete quadriceps rupture after total knee arthroplasty.

Scott R Nodzo1, Sridhar R Rachala2.   

Abstract

INTRODUCTION: Polypropylene mesh has previously been shown to be an effective treatment for failed patellar tendon repairs after total knee arthroplasty (TKA), but there have been few reports of this synthetic mesh used in complete quadriceps rupture after TKA.
METHODS: We retrospectively reviewed seven consecutive cases in six patients with complete quadriceps tears after TKA who had their quadriceps tendon repaired with suture and polypropylene mesh augmentation. All but two patients had previously failed primary suture repair. Patient outcomes were evaluated using the Knee Society Score. Standardized anterior-posterior (AP), lateral and merchant radiographs were evaluated preoperatively and at final follow-up.
RESULTS: Seven knees in six patients were evaluated with a mean follow-up of 34±10 (range 24 to 49months) months. There were only four clinical successes defined as an extensor lag less than 30°. Of the functioning knees at final follow-up (n=5) the overall extensor lag in this group did significantly improve from 50±13° to 20±15° (range 5 to 40°) (p=.01). Mean postoperative flexion at final follow-up was 115±8°. Mean Knee Society Score for function improved from 20±30 to 45±54 (p=.03) as did the mean Knee Society Score for pain (44±18 vs. 74±78, p=.02). DISCUSSION: Polypropylene mesh offered limited postoperative functional results when used as an augment to the multiply operated knee that sustains a complete quadriceps rupture after TKA, but did allow for significant improvement in postoperative pain outcomes. LEVEL OF EVIDENCE: IV.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Extensor mechanism; Polypropylene mesh; Quadriceps rupture; Total knee arthroplasty

Mesh:

Substances:

Year:  2015        PMID: 26746041     DOI: 10.1016/j.knee.2015.09.007

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  9 in total

1.  V-Y turndown flap augmentation for acute quadriceps rupture after total knee arthroplasty: a prospective matched cohort study.

Authors:  Francisco A Miralles-Muñoz; Marta Rubio-Morales; Matias Ruiz-Lozano; Daniel Martinez-Mendez; Santiago Gonzalez-Parreño; Alejandro Lizaur-Utrilla
Journal:  Int Orthop       Date:  2021-01-13       Impact factor: 3.075

2.  [Status and treatment of knee extension device disruption after total knee arthroplasty].

Authors:  Tiejian Li; Yinqiao Du; Jingyang Sun; Junmin Shen; Bohan Zhang; Yonggang Zhou
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-04-15

3.  Trapezoidal Achilles Tendon Allograft Plug for Revision Quadriceps Tendon Repair With a Large Tendon Defect.

Authors:  Kyle N Kunze; Robert A Burnett; Kevin K Shinsako; Charles A Bush-Joseph; Brian J Cole; Jorge Chahla
Journal:  Arthrosc Tech       Date:  2019-09-11

4.  Treatment of neglected quadriceps tendon ruptures using LARS™ ligament augmentation: A case series.

Authors:  Ms R Mahoney; K Veravalli; A Mofidi
Journal:  Trauma Case Rep       Date:  2021-02-18

Review 5.  Extensor mechanism failure in total knee arthroplasty.

Authors:  Jimmy Ng; Pau Balcells-Nolla; Peter J James; Benjamin V Bloch
Journal:  EFORT Open Rev       Date:  2021-03-01

6.  Synthetic Mesh Reconstruction of Chronic, Native Quadriceps Tendon Disruptions following Failed Primary Repair.

Authors:  Braden E Hartline; Jacob M Wilson; Andrew M Schwartz; James R Roberson; George N Guild
Journal:  Case Rep Orthop       Date:  2021-09-15

Review 7.  Complex ruptures of the quadriceps tendon: a systematic review of surgical procedures and outcomes.

Authors:  Francesco Oliva; Emanuela Marsilio; Filippo Migliorini; Nicola Maffulli
Journal:  J Orthop Surg Res       Date:  2021-09-04       Impact factor: 2.359

8.  Quadriceps or patellar ligament reconstruction with artificial ligament after total knee replacement.

Authors:  Lorenzo Ponziani; Francesco Tentoni; Francesco Di Caprio
Journal:  Acta Biomed       Date:  2022-03-10

9.  Suturing Achilles tendon and mesh simultaneously in augmented repair resists gap formation foremost: an experimental study.

Authors:  William McCartney; Ciprian Ober; Maria Benito; Bryan MacDonald
Journal:  J Orthop Surg Res       Date:  2019-10-24       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.