Literature DB >> 26741533

A comparison of stress in cracked fibrous tissue specimens with varied crack location, loading, and orientation using finite element analysis.

John M Peloquin1, Dawn M Elliott2.   

Abstract

Cracks in fibrous soft tissue, such as intervertebral disc annulus fibrosus and knee meniscus, cause pain and compromise joint mechanics. A crack concentrates stress at its tip, making further failure and crack extension (fracture) more likely. Ex vivo mechanical testing is an important tool for studying the loading conditions required for crack extension, but prior work has shown that it is difficult to reproduce crack extension. Most prior work used edge crack specimens in uniaxial tension, with the crack 90° to the edge of the specimen. This configuration does not necessarily represent the loading conditions that cause in vivo crack extension. To find a potentially better choice for experiments aiming to reproduce crack extension, we used finite element analysis to compare, in factorial combination, (1) center crack vs. edge crack location, (2) biaxial vs. uniaxial loading, and (3) crack-fiber angles ranging from 0° to 90°. The simulated material was annulus fibrosus fibrocartilage with a single fiber family. We hypothesized that one of the simulated test cases would produce a stronger stress concentration than the commonly used uniaxially loaded 90° crack-fiber angle edge crack case. Stress concentrations were compared between cases in terms of fiber-parallel stress (representing risk of fiber rupture), fiber-perpendicular stress (representing risk of matrix rupture), and fiber shear stress (representing risk of fiber sliding). Fiber-perpendicular stress and fiber shear stress concentrations were greatest in edge crack specimens (of any crack-fiber angle) and center crack specimens with a 90° crack-fiber angle. However, unless the crack is parallel to the fiber direction, these stress components alone are insufficient to cause crack opening and extension. Fiber-parallel stress concentrations were greatest in center crack specimens with a 45° crack-fiber angle, either biaxially or uniaxially loaded. We therefore recommend that the 45° center crack case be tried in future experiments intended to study crack extension by fiber rupture.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Crack propagation; Fibrocartilage; Finite element analysis; Tensile testing

Mesh:

Year:  2015        PMID: 26741533      PMCID: PMC4798902          DOI: 10.1016/j.jmbbm.2015.12.004

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  48 in total

1.  Fracture toughness estimation for the TMJ disc.

Authors:  Kittisak Koombua; Ramana M Pidaparti; Mark W Beatty
Journal:  J Biomed Mater Res A       Date:  2006-12-01       Impact factor: 4.396

2.  Failure mechanisms in fibrous scaffolds.

Authors:  C T Koh; D G T Strange; K Tonsomboon; M L Oyen
Journal:  Acta Biomater       Date:  2013-03-05       Impact factor: 8.947

3.  Internal three-dimensional strains in human intervertebral discs under axial compression quantified noninvasively by magnetic resonance imaging and image registration.

Authors:  Jonathon H Yoder; John M Peloquin; Gang Song; Nick J Tustison; Sung M Moon; Alexander C Wright; Edward J Vresilovic; James C Gee; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2014-11       Impact factor: 2.097

4.  Mechanical properties of human stratum corneum: effects of temperature, hydration, and chemical treatment.

Authors:  Kenneth S Wu; William W van Osdol; Reinhold H Dauskardt
Journal:  Biomaterials       Date:  2005-08-10       Impact factor: 12.479

5.  Fracture of articular cartilage.

Authors:  M V Chin-Purcell; J L Lewis
Journal:  J Biomech Eng       Date:  1996-11       Impact factor: 2.097

Review 6.  The long-term consequence of anterior cruciate ligament and meniscus injuries: osteoarthritis.

Authors:  L Stefan Lohmander; P Martin Englund; Ludvig L Dahl; Ewa M Roos
Journal:  Am J Sports Med       Date:  2007-08-29       Impact factor: 6.202

7.  Failure modes and fracture toughness in partially torn ligaments and tendons.

Authors:  Gregory A Von Forell; Peter S Hyoung; Anton E Bowden
Journal:  J Mech Behav Biomed Mater       Date:  2014-04-08

8.  Meniscal tear and extrusion are strongly associated with progression of symptomatic knee osteoarthritis as assessed by quantitative magnetic resonance imaging.

Authors:  M-J Berthiaume; J-P Raynauld; J Martel-Pelletier; F Labonté; G Beaudoin; D A Bloch; D Choquette; B Haraoui; R D Altman; M Hochberg; J M Meyer; G A Cline; J-P Pelletier
Journal:  Ann Rheum Dis       Date:  2004-09-16       Impact factor: 19.103

9.  Mode I and Mode III fractures in intermediate zone of full-thickness porcine temporomandibular joint discs.

Authors:  Mark W Beatty; Rebecca H Hohl; Jeffrey C Nickel; Laura R Iwasaki; Ramana M Pidaparti
Journal:  Ann Biomed Eng       Date:  2008-01-29       Impact factor: 3.934

Review 10.  Meniscal tears.

Authors:  Nicola Maffulli; Umile Giuseppe Longo; Stefano Campi; Vincenzo Denaro
Journal:  Open Access J Sports Med       Date:  2010-04-26
View more
  4 in total

1.  Structure, function, and defect tolerance with maturation of the radial tie fiber network in the knee meniscus.

Authors:  Sonia Bansal; John M Peloquin; Niobra M Keah; Olivia C O'Reilly; Dawn M Elliott; Robert L Mauck; Miltiadis H Zgonis
Journal:  J Orthop Res       Date:  2020-04-30       Impact factor: 3.494

Review 2.  Six-Month Outcomes of Clinically Relevant Meniscal Injury in a Large-Animal Model.

Authors:  Sonia Bansal; Kyle D Meadows; Liane M Miller; Kamiel S Saleh; Jay M Patel; Brendan D Stoeckl; Elisabeth A Lemmon; Michael W Hast; Miltiadis H Zgonis; Carla R Scanzello; Dawn M Elliott; Robert L Mauck
Journal:  Orthop J Sports Med       Date:  2021-11-12

3.  A novel mechanobiological model can predict how physiologically relevant dynamic loading causes proteoglycan loss in mechanically injured articular cartilage.

Authors:  Gustavo A Orozco; Petri Tanska; Cristina Florea; Alan J Grodzinsky; Rami K Korhonen
Journal:  Sci Rep       Date:  2018-10-22       Impact factor: 4.379

4.  Structural, compositional, and functional effects of blunt and sharp cartilage damage on the joint: A 9-month equine groove model study.

Authors:  Nikae C R Te Moller; Ali Mohammadi; Saskia Plomp; Filipe M Serra Bragança; Martijn Beukers; Behdad Pouran; Isaac O Afara; Ervin Nippolainen; Janne T A Mäkelä; Rami K Korhonen; Juha Töyräs; Harold Brommer; P René van Weeren
Journal:  J Orthop Res       Date:  2021-01-23       Impact factor: 3.494

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.