Literature DB >> 26739827

Self-expanding Portico Valve Versus Balloon-expandable SAPIEN XT Valve in Patients With Small Aortic Annuli: Comparison of Hemodynamic Performance.

María Del Trigo1, Abdellaziz Dahou1, John G Webb2, Danny Dvir2, Rishi Puri1, Omar Abdul-Jawad Altisent1, Francisco Campelo-Parada1, Chris Thompson2, Jonathon Leipsic2, Dion Stub2, Robert DeLarochellière1, Jean-Michel Paradis1, Eric Dumont1, Daniel Doyle1, Siamak Mohammadi1, Sergio Pasian1, Melanie Côté1, Philippe Pibarot1, Josep Rodés-Cabau3.   

Abstract

INTRODUCTION AND
OBJECTIVES: The self-expanding Portico valve is a new transcatheter aortic valve system yielding promising preliminary results, yet there are no comparative data against earlier generation transcatheter aortic valve systems. The aim of this study was to compare the hemodynamic performance of the Portico and balloon-expandable SAPIEN XT valves in a case-matched study with echocardiographic core laboratory analysis.
METHODS: Twenty-two patients underwent transcatheter aortic valve implantation with the Portico 23-mm valve and were matched for aortic annulus area and mean diameter measured by multidetector computed tomography, left ventricular ejection fraction, body surface area, and body mass index with 40 patients treated with the 23-mm SAPIEN XT. Mean aortic annulus diameters were 19.6±1.3mm by transthoracic echocardiography and 21.4±1.2mm by computed tomography, with no significant between-group differences. Doppler echocardiographic images were collected at baseline and at 1-month of follow-up and were analyzed in a central echocardiography core laboratory.
RESULTS: There were no significant between-group differences in residual mean transaortic gradients (SAPIEN XT: 10.4±3.7mmHg; Portico: 9.8±1.1mmHg; P=.49) and effective orifice areas (SAPIEN XT: 1.36±0.27cm(2); Portico, 1.37±.29cm(2); P=.54). Rates of severe prosthesis-patient mismatch (effective orifice area<0.65cm(2)/m(2)) were similar (SAPIEN XT: 13.5%; Portico: 10.0%; P=.56). No between-group differences were found in the occurrence of moderate-severe paravalvular leaks (5.0% vs 4.8% of SAPIEN XT and Portico respectively; P=.90).
CONCLUSIONS: Transcatheter aortic valve implantation with the self-expanding Portico system yielded similar short-term hemodynamic performance compared with the balloon-expandable SAPIEN XT system for treating patients with severe aortic stenosis and small annuli. Further prospective studies with longer-term follow-up and in patients with larger aortic annuli are required.
Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Aortic regurgitation; Aortic stenosis; Desajuste prótesis-paciente; Estenosis aórtica; Implante percutáneo de válvula aórtica; Insuficiencia aórtica; Prosthesis-patient mismatch; Transcatheter aortic valve implantation

Mesh:

Year:  2015        PMID: 26739827     DOI: 10.1016/j.rec.2015.08.019

Source DB:  PubMed          Journal:  Rev Esp Cardiol (Engl Ed)        ISSN: 1885-5857


  5 in total

1.  Head to head transcatheter heart valve comparisons: when theory becomes reality.

Authors:  Gabriela Tirado-Conte; German Armijo; Luis Nombela-Franco
Journal:  Cardiovasc Diagn Ther       Date:  2018-08

2.  An in vitro evaluation of turbulence after transcatheter aortic valve implantation.

Authors:  Hoda Hatoum; Atieh Yousefi; Scott Lilly; Pablo Maureira; Juan Crestanello; Lakshmi P Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2018-06-02       Impact factor: 5.209

Review 3.  The Medical Devices Special Access Program in Canada: A Scoping Study.

Authors:  Roland K Maier; Devidas Menon; Tania Stafinski
Journal:  Healthc Policy       Date:  2018-02

Review 4.  Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Authors:  Pier Pasquale Leone; Fabio Fazzari; Francesco Cannata; Jorge Sanz-Sanchez; Antonio Mangieri; Lorenzo Monti; Ottavia Cozzi; Giulio Giuseppe Stefanini; Renato Bragato; Antonio Colombo; Bernhard Reimers; Damiano Regazzoli
Journal:  Front Cardiovasc Med       Date:  2021-06-04

5.  Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis.

Authors:  Yan-Biao Liao; Yi-Jian Li; Li Jun-Li; Zhen-Gang Zhao; Xin Wei; Jiay-Yu Tsauo; Tian-Yuan Xiong; Yuan-Ning Xu; Yuan Feng; Mao Chen
Journal:  Sci Rep       Date:  2017-11-08       Impact factor: 4.379

  5 in total