OBJECTIVE/
BACKGROUND: To evaluate if the creation of laser generated in situ fenestrations in polyester/Dacron stent grafts causes embolization.
METHODS: In seven pigs, Dacron stent grafts were implanted from the infrarenal aorta to the right iliac artery. Prior to placing the stent graft, a carotid artery protection filter, with a pore size of 70-200 μm, was placed in the proximal left common iliac artery. An excimer laser catheter was then advanced antegradely through the stent graft and positioned at the level of origin of the left iliac artery. A fenestration was then created with the laser probe. The carotid filter was retrieved and inspected macroscopically with magnifying glasses, for emboli and clot.
RESULTS: Seven pigs with a median weight of 90 kg (range 78-98 kg) were tested. The median operating time was 170 minutes. All laser fenestrations were successfully completed. No emboli or clot could be detected in the protection filters.
CONCLUSION: Creation of laser generated, in situ fenestrations do not produce macroscopically visible emboli/clot. This might indicate safe usage of laser created fenestrations for endovascular arch repair and left subclavian artery revascularization.
Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dacron stent grafts; Embolic complications; In situ fenestration; Laser

Mesh:

Substances:

Year:  2015        PMID: 26739804     DOI: 10.1016/j.ejvs.2015.11.014

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  5 in total

1.  An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm.

Authors:  Kota Shukuzawa; Takeshi Baba; Ryosuke Nishie; Hirotsugu Ozawa; Makiko Omori; Masayuki Hara; Hiromasa Tachihara; Takao Ohki
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-05-12

2.  Endovascular treatment for aortic arch pathologies: chimney, on-the-table fenestration, and in-situ fenestration techniques.

Authors:  Chang Shu; Bowen Fan; Mingyao Luo; Quanming Li; Kun Fang; Ming Li; Xin Li; Hao He; Tun Wang; Chenzi Yang; Yunfei Xue; Haoyu Gao; Jiawei Zhao
Journal:  J Thorac Dis       Date:  2020-04       Impact factor: 2.895

Review 3.  Special Features of Polyester-Based Materials for Medical Applications.

Authors:  Raluca Nicoleta Darie-Niță; Maria Râpă; Stanisław Frąckowiak
Journal:  Polymers (Basel)       Date:  2022-02-27       Impact factor: 4.329

4.  In Situ Laser Fenestration Is a Feasible Method for Revascularization of Aortic Arch During Thoracic Endovascular Aortic Repair.

Authors:  Jinbao Qin; Zhen Zhao; Ruihua Wang; Kaichuang Ye; Weimin Li; Xiaobing Liu; Guang Liu; Chaoyi Cui; Huihua Shi; Zhiyou Peng; Fukang Yuan; Xinrui Yang; Min Lu; Xintian Huang; Mier Jiang; Xin Wang; Minyi Yin; Xinwu Lu
Journal:  J Am Heart Assoc       Date:  2017-04-21       Impact factor: 5.501

5.  Case report of retrograde in situ fenestration of the thoracic stent graft with reentry device in a patient with aortobronchial fistula.

Authors:  Alexander D Leung; Dai Yamanouchi
Journal:  Medicine (Baltimore)       Date:  2018-06       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.