Literature DB >> 26738173

Evaluation of the beat-to-beat detection accuracy of PulseOn wearable optical heart rate monitor.

Jakub Parak, Adrian Tarniceriu, Philippe Renevey, Mattia Bertschi, Ricard Delgado-Gonzalo, Ilkka Korhonen.   

Abstract

Heart rate variability (HRV) provides significant information about the health status of an individual. Optical heart rate monitoring is a comfortable alternative to ECG based heart rate monitoring. However, most available optical heart rate monitoring devices do not supply beat-to-beat detection accuracy required by proper HRV analysis. We evaluate the beat-to-beat detection accuracy of a recent wrist-worn optical heart rate monitoring device, PulseOn (PO). Ten subjects (8 male and 2 female; 35.9±10.3 years old) participated in the study. HRV was recorded with PO and Firstbeat Bodyguard 2 (BG2) device, which was used as an ECG based reference. HRV was recorded during sleep. As compared to BG2, PO detected on average 99.57% of the heartbeats (0.43% of beats missed) and had 0.72% extra beat detection rate, with 5.94 ms mean absolute error (MAE) in beat-to-beat intervals (RRI) as compared to the ECG based RRI BG2. Mean RMSSD difference between PO and BG2 derived HRV was 3.1 ms. Therefore, PO provides an accurate method for long term HRV monitoring during sleep.

Mesh:

Year:  2015        PMID: 26738173     DOI: 10.1109/EMBC.2015.7320273

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  17 in total

Review 1.  Sensors Capabilities, Performance, and Use of Consumer Sleep Technology.

Authors:  Massimiliano de Zambotti; Nicola Cellini; Luca Menghini; Michela Sarlo; Fiona C Baker
Journal:  Sleep Med Clin       Date:  2020-01-03

2.  Evaluating commercially available wireless cardiovascular monitors for measuring and transmitting real-time physiological responses in children with autism.

Authors:  Heather J Nuske; Matthew S Goodwin; Yelena Kushleyeva; Daniel Forsyth; Jeffrey W Pennington; Aaron J Masino; Emma Finkel; Anushua Bhattacharya; Jessica Tan; Hungtzu Tai; Zabryna Atkinson-Diaz; Christopher P Bonafide; John D Herrington
Journal:  Autism Res       Date:  2021-11-06       Impact factor: 4.633

3.  Pulse Rate Measurement During Sleep Using Wearable Sensors, and its Correlation with the Menstrual Cycle Phases, A Prospective Observational Study.

Authors:  Mohaned Shilaih; Valérie de Clerck; Lisa Falco; Florian Kübler; Brigitte Leeners
Journal:  Sci Rep       Date:  2017-05-02       Impact factor: 4.379

4.  Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables.

Authors:  André Henriksen; Martin Haugen Mikalsen; Ashenafi Zebene Woldaregay; Miroslav Muzny; Gunnar Hartvigsen; Laila Arnesdatter Hopstock; Sameline Grimsgaard
Journal:  J Med Internet Res       Date:  2018-03-22       Impact factor: 5.428

5.  Digital biomarkers for Alzheimer's disease: the mobile/ wearable devices opportunity.

Authors:  Lampros C Kourtis; Oliver B Regele; Justin M Wright; Graham B Jones
Journal:  NPJ Digit Med       Date:  2019-02-21

6.  Speckleplethysmographic (SPG) Estimation of Heart Rate Variability During an Orthostatic Challenge.

Authors:  Cody E Dunn; Derek C Monroe; Christian Crouzet; James W Hicks; Bernard Choi
Journal:  Sci Rep       Date:  2019-10-01       Impact factor: 4.379

7.  The Promise of Sleep: A Multi-Sensor Approach for Accurate Sleep Stage Detection Using the Oura Ring.

Authors:  Marco Altini; Hannu Kinnunen
Journal:  Sensors (Basel)       Date:  2021-06-23       Impact factor: 3.576

8.  Big data analytics for preventive medicine.

Authors:  Muhammad Imran Razzak; Muhammad Imran; Guandong Xu
Journal:  Neural Comput Appl       Date:  2019-03-16       Impact factor: 5.102

9.  Stress Detection Using Low Cost Heart Rate Sensors.

Authors:  Mario Salai; István Vassányi; István Kósa
Journal:  J Healthc Eng       Date:  2016       Impact factor: 2.682

10.  A "Wearable" Test for Maximum Aerobic Power: Real-Time Analysis of a 60-m Sprint Performance and Heart Rate Off-Kinetics.

Authors:  Jorge L Storniolo; Gaspare Pavei; Alberto E Minetti
Journal:  Front Physiol       Date:  2017-11-01       Impact factor: 4.566

View more