Robot assisted stapedotomy ex vivo with an active handheld instrument.

Tobia Vendrametto, Jacob S McAfee, Barry E Hirsch, Cameron N Riviere, Giancarlo Ferrigno, Elena De Momi.   

Abstract

Micron is a fully handheld active micromanipulator that helps to improve position accuracy and precision in microsurgery by cancelling hand tremor. This work describes adaptation, tuning, and testing of the Micron system for stapedotomy, a microsurgical procedure performed in the middle ear to restore hearing that requires accurate manipulation in narrow spaces. Two end-effectors, a handle, and a brace (or rest) were designed and prototyped. The control system was adapted for the new hardware. The system was tested ex vivo in stapedotomy procedure comparing manually-performed and Micron-assisted surgical tasks. Tremor amplitude was found to be reduced significantly. Further testing is needed in order to obtain statistically significant results regarding other parameters dealing with regularity of the fenestra shape.

Entities:  

Mesh:

Year:  2015        PMID: 26737386      PMCID: PMC4704113          DOI: 10.1109/EMBC.2015.7319486

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  10 in total

1.  Robot-assisted stapedotomy: micropick fenestration of the stapes footplate.

Authors:  Daniel L Rothbaum; Jaydeep Roy; Dan Stoianovici; Peter Berkelman; Gregory D Hager; Russell H Taylor; Louis L Whitcomb; Howard W Francis; John K Niparko
Journal:  Otolaryngol Head Neck Surg       Date:  2002-11       Impact factor: 3.497

2.  Reconstructive Middle Ear Surgery: Techniques to improve hearing.

Authors:  R R Ruby; R H Ballagh
Journal:  Can Fam Physician       Date:  1992-11       Impact factor: 3.275

3.  Handheld micromanipulator for robot-assisted stapes footplate surgery.

Authors:  Gonzalo Montes Grande; Anna J Knisely; Brian C Becker; Sungwook Yang; Barry E Hirsch; Cameron N Riviere
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

4.  Vision-Based Control of a Handheld Surgical Micromanipulator with Virtual Fixtures.

Authors:  Brian C Becker; Robert A Maclachlan; Louis A Lobes; Gregory D Hager; Cameron N Riviere
Journal:  IEEE Trans Robot       Date:  2013-02-19       Impact factor: 5.567

Review 5.  Hand-held medical robots.

Authors:  Christopher J Payne; Guang-Zhong Yang
Journal:  Ann Biomed Eng       Date:  2014-06-14       Impact factor: 3.934

6.  Comparison of Baseline Tremor Under Various Microsurgical Conditions.

Authors:  Trent S Wells; Sungwook Yang; Robert A Maclachlan; James T Handa; Peter Gehlbach; Cameron Riviere
Journal:  Conf Proc IEEE Int Conf Syst Man Cybern       Date:  2013

7.  Micron: an Actively Stabilized Handheld Tool for Microsurgery.

Authors:  Robert A Maclachlan; Brian C Becker; Jaime Cuevas Tabarés; Gregg W Podnar; Louis A Lobes; Cameron N Riviere
Journal:  IEEE Trans Robot       Date:  2011-11-18       Impact factor: 5.567

8.  High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing.

Authors:  Robert A Maclachlan; Cameron N Riviere
Journal:  IEEE Trans Instrum Meas       Date:  2009-06-01       Impact factor: 4.016

9.  Forty years of stapes surgery.

Authors:  J J Shea
Journal:  Am J Otol       Date:  1998-01

10.  Design, kinematic optimization, and evaluation of a teleoperated system for middle ear microsurgery.

Authors:  Mathieu Miroir; Yann Nguyen; Jérôme Szewczyk; Olivier Sterkers; Alexis Bozorg Grayeli
Journal:  ScientificWorldJournal       Date:  2012-08-13
  10 in total
  1 in total

1.  In Situ Tremor in Vitreoretinal Surgery.

Authors:  Yifan Li; Mitchell D Wolf; Amol D Kulkarni; James Bell; Jonathan S Chang; Amit Nimunkar; Robert G Radwin
Journal:  Hum Factors       Date:  2020-04-14       Impact factor: 2.888

  1 in total