| Literature DB >> 26737105 |
James D Amor, John G Hattersley, Thomas M Barber, Christopher J James.
Abstract
Physical activity (PA) is a significant factor in a number of health conditions and monitoring PA can play a significant role in the treatment of, or research into, these conditions. For longitudinal monitoring of PA, unobtrusive devices are often used and there is a need for the development of energy expenditure (EE) estimation techniques from single-device systems. This paper presents an experiment designed to characterize the relationship between a previously described technique, the activity score (AS) and EE obtained from whole-room indirect calorimetry. The study used 8 participants over a 24-hr period with interspersed exercise periods to observe physical movement with wearable devices and EE in 5 minute epochs. Results show that AS and EE are correlated with a Spearman's rank correlation coefficient of 0.775 with p <; 0.001.Entities:
Mesh:
Year: 2015 PMID: 26737105 DOI: 10.1109/EMBC.2015.7319205
Source DB: PubMed Journal: Conf Proc IEEE Eng Med Biol Soc ISSN: 1557-170X