Eliminating pulse-induced artifacts in Urethral Pressure data.

Mario Klunder, Ronny Feuer, Bastian Amend, Alexandra Kelp, Arnulf Stenzl, Karl-Dietrich Sievert, Oliver Sawodny, Michael Ederer.   

Abstract

Urethral Pressure Profilometry (UPP) is a tool in the diagnosis of urinary incontinence. The pressure profile along the urethra is measured by a special catheter in order to assess the contraction strength of the sphincter muscle. The use of microtip catheters with several pressure sensors and an integrated acceleration sensor enables signal reconstruction of the pressure distribution on the urethra's inside. Experimental data from minipigs exhibit artifact patterns in the pressure data. It is shown that these artifacts are caused by vascular pulsation in the sphincter structure. We therefore investigate different methods exploiting the time-correlation of the artifacts to eliminate pulse-induced artifacts in the pressure data without compromising the actual signal. Evaluation of these methods applied to experimental data conclude this work showing that both an Input-Model and Principal Component Analysis Decorrelation are effective at removing the artifacts.

Entities:  

Mesh:

Year:  2015        PMID: 26736868     DOI: 10.1109/EMBC.2015.7318968

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Establishing and monitoring of urethral sphincter deficiency in a large animal model.

Authors:  Alexandra Kelp; Anika Albrecht; Bastian Amend; Mario Klünder; Philipp Rapp; Oliver Sawodny; Arnulf Stenzl; Wilhelm K Aicher
Journal:  World J Urol       Date:  2017-09-22       Impact factor: 4.226

2.  Novel insight into pressurization of the male and female urethra through application of a multi-channel fibre-optic pressure transducer: Proof of concept and validation.

Authors:  Ryan E Stafford; John Arkwright; Phil G Dinning; Wolbert van den Hoorn; Paul W Hodges
Journal:  Investig Clin Urol       Date:  2020-09

3.  Signal processing in urodynamics: towards high definition urethral pressure profilometry.

Authors:  Mario Klünder; Oliver Sawodny; Bastian Amend; Michael Ederer; Alexandra Kelp; Karl-Dietrich Sievert; Arnulf Stenzl; Ronny Feuer
Journal:  Biomed Eng Online       Date:  2016-03-22       Impact factor: 2.819

4.  Scaling Relationship of In Vivo Muscle Contraction Strength of Rabbits Exposed to High-Frequency Nanosecond Pulse Bursts.

Authors:  Yan Mi; Jin Xu; Xuefeng Tang; Changhao Bian; Hongliang Liu; Qiyu Yang; Junying Tang
Journal:  Technol Cancer Res Treat       Date:  2018-01-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.