Literature DB >> 26736293

Congestive heart failure patient monitoring using wearable Bio-impedance sensor technology.

Gabriel Squillace, Christophe Smeets, Marianne Vandecasteele, Lars Grieten, Ruben de Francisco, Chris Van Hoof.   

Abstract

A new technique to monitor the fluid status of congestive heart failure (CHF) patients in the hospital is proposed and verified in a clinical trial with 8 patients. A wearable Bio-impedance (BioZ) sensor allows a continuous localized measurement which can be complement clinical tools in the hospital. Thanks to the multi-parametric approach and correlation analysis with clinical reference, BioZ is successfully shown as a promising parameter for continuous and wearable CHF patient monitoring application.

Entities:  

Mesh:

Year:  2015        PMID: 26736293     DOI: 10.1109/EMBC.2015.7318393

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  6 in total

1.  Wearables for the Next Pandemic.

Authors:  Ava Hedayatipour; Nicole Mcfarlane
Journal:  IEEE Access       Date:  2020-10-06       Impact factor: 3.367

Review 2.  Wearable Devices for Physical Monitoring of Heart: A Review.

Authors:  Guillermo Prieto-Avalos; Nancy Aracely Cruz-Ramos; Giner Alor-Hernández; José Luis Sánchez-Cervantes; Lisbeth Rodríguez-Mazahua; Luis Rolando Guarneros-Nolasco
Journal:  Biosensors (Basel)       Date:  2022-05-02

Review 3.  The Role of Wearables in Heart Failure.

Authors:  Arvind Singhal; Martin R Cowie
Journal:  Curr Heart Fail Rep       Date:  2020-08

Review 4.  Mobile Phone Apps to Support Heart Failure Self-Care Management: Integrative Review.

Authors:  Ponrathi Athilingam; Bradlee Jenkins
Journal:  JMIR Cardio       Date:  2018-05-02

5.  Towards personalized fluid monitoring in haemodialysis patients: thoracic bioimpedance signal shows strong correlation with fluid changes, a cohort study.

Authors:  Melanie K Schoutteten; Julie Vranken; Seulki Lee; Christophe J P Smeets; Hélène De Cannière; Chris Van Hoof; Jacques Peeters; Willemijn Groenendaal; Pieter M Vandervoort
Journal:  BMC Nephrol       Date:  2020-07-11       Impact factor: 2.388

6.  The Added Value of In-Hospital Tracking of the Efficacy of Decongestion Therapy and Prognostic Value of a Wearable Thoracic Impedance Sensor in Acutely Decompensated Heart Failure With Volume Overload: Prospective Cohort Study.

Authors:  Christophe J P Smeets; Seulki Lee; Willemijn Groenendaal; Gabriel Squillace; Julie Vranken; Hélène De Cannière; Chris Van Hoof; Lars Grieten; Wilfried Mullens; Petra Nijst; Pieter M Vandervoort
Journal:  JMIR Cardio       Date:  2020-03-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.