Literature DB >> 26736255

Simulation of Transcatheter Aortic Valve Replacement in patient-specific aortic roots: Effect of crimping and positioning on device performance.

Matteo Bianchi, Ram P Ghosh, Gil Marom, Marvin J Slepian, Danny Bluestein.   

Abstract

Calcific aortic valve disease (CAVD) is a cardiovascular condition that causes the progressive narrowing of the aortic valve (AV) opening, due to the growth of bone-like deposits all over the aortic root (AR). Transcatheter aortic valve replacement (TAVR), a minimally invasive procedure, has recently become the only lifesaving solution for patients that cannot tolerate the standard surgical valve replacement. However, adverse effects, such as AR injury or paravalvular leakage (PVL), may occur as a consequence of a sub-optimal procedure, due to the presence of calcifications in situ. Additionally, the crimping required for delivering the valve via stenting may damage the valve. The aim of the present study is to comparatively assess the crimping mechanics of the commercialized Edwards SAPIEN valve and an alternative polymeric valve (Polynova, Inc) and to evaluate the effect of different TAVR deployment positions using patient-specific numerical models. The optimal deployment location for achieving better patient outcomes was calculated and based on the interactions between the TAVR stent and the native AR. Results demonstrated that the Polynova valve withstands the crimping process better than the SAPIEN valve. Furthermore, deployment simulations showed the role that calcifications deposits may play in the TAVR sub-optimal valve anchoring to the AV wall, leading to the presence of gaps that result in PVL.

Entities:  

Mesh:

Year:  2015        PMID: 26736255     DOI: 10.1109/EMBC.2015.7318355

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  7 in total

1.  In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve.

Authors:  Megan Heitkemper; Hoda Hatoum; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2019-06-19

Review 2.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

Review 3.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

4.  An in vitro evaluation of turbulence after transcatheter aortic valve implantation.

Authors:  Hoda Hatoum; Atieh Yousefi; Scott Lilly; Pablo Maureira; Juan Crestanello; Lakshmi P Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2018-06-02       Impact factor: 5.209

5.  In Vitro Durability and Stability Testing of a Novel Polymeric Transcatheter Aortic Valve.

Authors:  Oren M Rotman; Brandon Kovarovic; Matteo Bianchi; Marvin J Slepian; Danny Bluestein
Journal:  ASAIO J       Date:  2020-02       Impact factor: 3.826

6.  Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case.

Authors:  Adi A Basri; Mohammad Zuber; Ernnie I Basri; Muhammad S Zakaria; Ahmad F A Aziz; Masaaki Tamagawa; Kamarul A Ahmad
Journal:  Comput Math Methods Med       Date:  2020-05-04       Impact factor: 2.238

Review 7.  Three-dimensional printing for heart diseases: clinical application review.

Authors:  Yanyan Ma; Peng Ding; Lanlan Li; Yang Liu; Ping Jin; Jiayou Tang; Jian Yang
Journal:  Biodes Manuf       Date:  2021-04-30
  7 in total