Literature DB >> 26735870

A novel electrochemical immunosensor based on the rGO-TEPA-PTC-NH₂ and AuPt modified C₆₀ bimetallic nanoclusters for the detection of Vangl1, a potential biomarker for dysontogenesis.

Qiutong Chen1, Chao Yu1, Rufei Gao1, Liuliu Gao1, Qingying Li1, Guolin Yuan1, Junlin He2.   

Abstract

The aberrant expression of Vangl1 is highly correlated with dysontogenesis, especially for neural tube defects. Therefore, the ultrasensitive detection of Vangl1 would provide a new approach for the specific early diagnostics in dysembryoplasia. However, no quantitative detection method is currently available. Herein, we describe the development of a new approach to fill this assay gap. We utilized C60-templated AuPt bimetallic nanoclusters for signal amplification because the promising C60 nanomaterial provides a large surface area for the in site reduction of bimetallic nanocomposites as well as excellent conductivity. To further amplify the electrochemical signal, reduced graphene oxide-tetraethylene pentamine (rGO-TEPA) and a derivative of 3,4,9,10-perylenetetracarboxylicdianhydride (PTC-NH2) were selected for modification of the electrode to provide more amino groups for the immobilization of antibodies and to enhance the conductivity. The electrochemical signal was primarily derived from the catalysis of H2O2 by C60-AuPt. Chronoamperometry was applied to record the electrochemical signals. Under optimal conditions, the prepared immunosensor exhibited a wide linear range from 0.1 pg mL(-1) to 450 pg mL(-1) and a low detection limit of 0.03 pg mL(-1). Moreover, the proposed method exhibited good stability and recovery, suggesting its potential for use in clinical research.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  AuPt bimetallic; Dysontogenesis; Electrochemical catalysis; Reduced graphene oxide-tetraethylene; Vangl1

Mesh:

Substances:

Year:  2015        PMID: 26735870     DOI: 10.1016/j.bios.2015.12.063

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Recent Advances in Electrochemical Immunosensors.

Authors:  Benoît Piro; Steeve Reisberg
Journal:  Sensors (Basel)       Date:  2017-04-07       Impact factor: 3.576

2.  A voltammetric immunosensor for clenbuterol based on the use of a MoS2-AuPt nanocomposite.

Authors:  Renyue Ji; Shuai Chen; Wei Xu; Zhen Qin; Jing Fu Qiu; Chao Rui Li
Journal:  Mikrochim Acta       Date:  2018-03-06       Impact factor: 5.833

3.  Sunflower-Like Nanostructure with Built-In Hotspots for Alpha-Fetoprotein Detection.

Authors:  Xiaoyu Zhao; Aonan Zhu; Yaxin Wang; Yongjun Zhang; Xiaolong Zhang
Journal:  Molecules       Date:  2021-02-23       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.