Literature DB >> 26733393

Conventional and enantioselective gas chromatography with microfabricated planar columns for analysis of real-world samples of plant volatile fraction.

C Cagliero1, S Galli2, M Galli2, I Elmi3, M Belluce3, S Zampolli3, B Sgorbini1, P Rubiolo1, C Bicchi4.   

Abstract

Within a project exploring the application of lab-on-chip GC to in-field analysis of the plant volatile fraction, this study evaluated the performance of a set of planar columns (also known as microchannels, MEMS columns, or microfabricated columns) of different dimensions installed in a conventional GC unit. Circular double-spiral-shaped-channel planar columns with different square/rectangular sections up to 2m long were applied to the analysis of both essential oils and headspace samples of a group of medicinal and aromatic plants (chamomile, peppermint, sage, rosemary, lavender and bergamot) and of standard mixtures of related compounds; the results were compared to those obtained with reference narrow-bore columns (l:5m, dc:0.1mm, df:0.1 μm). The above essential oils and headspaces were first analyzed quali-and quantitatively with planar columns statically coated with conventional stationary phases (5%-phenyl-polymethylsiloxane and auto-bondable nitroterephthalic-acid-modified polyethylene glycol), and then submitted to chiral recognition of their diagnostic markers, by enantioselective GC with a planar columns coated with a cyclodextrin derivative (30% 6(I-VII)-O-TBDMS-3(I-VII)-O-ethyl-2(I-VII)-O-ethyl-β-cyclodextrin in PS-086). Column characteristics and analysis conditions were first optimized to obtain suitable retention and efficiency for the samples investigated. The planar columns tested showed performances close to the reference conventional narrow-bore columns, with theoretical plate numbers per meter (N/m) ranging from 6100 to 7200 for those coated with the conventional stationary phases, and above 5600 for those with the chiral selector.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Essential oils; Headspace sampling; Micro-GC; Planar columns; Plant volatile fraction

Mesh:

Substances:

Year:  2015        PMID: 26733393     DOI: 10.1016/j.chroma.2015.12.037

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  1 in total

1.  A MEMS-Enabled Deployable Trace Chemical Sensor Based on Fast Gas-Chromatography and Quartz Enhanced Photoacousic Spectoscopy.

Authors:  Stefano Zampolli; Sandro Mengali; Nicola Liberatore; Ivan Elmi; Luca Masini; Michele Sanmartin; Roberto Viola
Journal:  Sensors (Basel)       Date:  2019-12-24       Impact factor: 3.576