Vertebral body fracture after anterior cervical discectomy and fusion with zero-profile anchored cages in adjacent levels: a cautionary tale.

Tobias A Mattei1, Alisson R Teles2, Dzung H Dinh3.   

Abstract

BACKGROUND CONTEXT: Zero-profile (also called self-locking, anchored or stand-alone cages) have been recently proposed as an interesting alternative for anterior cervical discectomy and fusion (ACDF), as they are supposed to reduce the rates of post-operative cage extrusion without necessarily incurring in the additional surgical time and increased rates of dysphagia associated with plating. Nevertheless, the exact indications of zero-profile anchored cages have not yet been established in the literature.
PURPOSE: To report the first case of a vertebral body fracture between the blades of zero-profile anchored cages after ACDFs in adjacent levels and to review the available literature on hardware-related complications after multi-level ACDFs with zero-profile anchored cages. STUDY
DESIGN: Case report and systematic literature review.
METHODS: The authors report the first case of a vertebral body fracture between the blades of zero-profile anchored cages after ACDFs in adjacent levels. The patient presented with refractory mechanical neck pain at the 1-month post-operative follow-up, ultimately requiring a posterior instrumented fusion. A comprehensive systematic literature review on the available data regarding the safety, complications as well as radiological and clinical outcomes of zero-profile anchored cages is also performed.
RESULTS: In the reported case, the use of zero-profile anchored cages in adjacent levels on the cervical spine led to a fracture of the vertebral body between the cages at the 1-month follow-up, with anterior avulsion of the part of the vertebral body where the blades from the two cages converged. According to the systematic literature review which included 409 patients from 10 different clinical series (with a total cumulative follow-up of approximately 535 patients-year), there were only two reported hardware-related complications after ACDF with zero-profile anchored cages, none of them involving fracture at the level of convergence of blades or screws.
CONCLUSIONS: Although hardware-related complications after the use of zero-profile anchored cages seem to be rare events, future biomechanical and clinical studies are warranted in order to evaluate the safety of employing such devices for the treatment of multilevel degenerative disc disease in the cervical spine.

Entities:  

Keywords:  Anchored cages; Anterior cervical discectomy and fusion; Anterior cervical plating; Self-locking cages; Zero-profile cages

Mesh:

Year:  2016        PMID: 26733015     DOI: 10.1007/s00586-015-4358-3

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  2 in total

1.  Comparison of a zero-profile anchored spacer (ROI-C) and the polyetheretherketone (PEEK) cages with an anterior plate in anterior cervical discectomy and fusion for multilevel cervical spondylotic myelopathy.

Authors:  Yijie Liu; Heng Wang; Xuefeng Li; Jie Chen; Han Sun; Genlin Wang; Huilin Yang; Weimin Jiang
Journal:  Eur Spine J       Date:  2016-03-11       Impact factor: 3.134

2.  Classification of three-level hybrid surgery for the treatment of cervical degenerative disc disease: a retrospective study of 108 patients.

Authors:  Kangkang Huang; Han Wang; Hao Liu; Yang Meng; Chen Ding; Beiyu Wang; Tingkui Wu; Ying Hong
Journal:  BMC Surg       Date:  2022-05-14       Impact factor: 2.030