Regularity analysis of nocturnal oximetry recordings to assist in the diagnosis of sleep apnoea syndrome.

J Víctor Marcos1, Roberto Hornero2, Ian T Nabney3, Daniel Álvarez4, Gonzalo C Gutiérrez-Tobal5, Félix del Campo6.   

Abstract

The relationship between sleep apnoea-hypopnoea syndrome (SAHS) severity and the regularity of nocturnal oxygen saturation (SaO2) recordings was analysed. Three different methods were proposed to quantify regularity: approximate entropy (AEn), sample entropy (SEn) and kernel entropy (KEn). A total of 240 subjects suspected of suffering from SAHS took part in the study. They were randomly divided into a training set (96 subjects) and a test set (144 subjects) for the adjustment and assessment of the proposed methods, respectively. According to the measurements provided by AEn, SEn and KEn, higher irregularity of oximetry signals is associated with SAHS-positive patients. Receiver operating characteristic (ROC) and Pearson correlation analyses showed that KEn was the most reliable predictor of SAHS. It provided an area under the ROC curve of 0.91 in two-class classification of subjects as SAHS-negative or SAHS-positive. Moreover, KEn measurements from oximetry data exhibited a linear dependence on the apnoea-hypopnoea index, as shown by a correlation coefficient of 0.87. Therefore, these measurements could be used for the development of simplified diagnostic techniques in order to reduce the demand for polysomnographies. Furthermore, KEn represents a convincing alternative to AEn and SEn for the diagnostic analysis of noisy biomedical signals.
Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Approximate entropy; Density estimation; Entropy rate; Kernel entropy; Oxygen saturation; Sample entropy

Mesh:

Substances:

Year:  2015        PMID: 26719242     DOI: 10.1016/j.medengphy.2015.11.010

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  1 in total

1.  Wearable Finger Pulse Oximetry for Continuous Oxygen Saturation Measurements During Daily Home Routines of Patients With Chronic Obstructive Pulmonary Disease (COPD) Over One Week: Observational Study.

Authors:  Joren Buekers; Jan Theunis; Patrick De Boever; Anouk W Vaes; Maud Koopman; Eefje Vm Janssen; Emiel Fm Wouters; Martijn A Spruit; Jean-Marie Aerts
Journal:  JMIR Mhealth Uhealth       Date:  2019-06-06       Impact factor: 4.773

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.