Literature DB >> 26717850

Ionic liquid-based zinc oxide nanofluid for vortex assisted liquid liquid microextraction of inorganic mercury in environmental waters prior to cold vapor atomic fluorescence spectroscopic detection.

Meseret Amde1, Jing-Fu Liu2, Zhi-Qiang Tan3, Deribachew Bekana1.   

Abstract

Zinc oxide nanofluid (ZnO-NF) based vortex assisted liquid liquid microextraction (ZnO-NF VA-LLME) was developed and employed in extraction of inorganic mercury (Hg(2+)) in environmental water samples, followed by cold vapor atomic fluorescence spectrometry (CV-AFS). Unlike other dispersive liquid liquid microextraction techniques, ZnO-NF VA-LLME is free of volatile organic solvents and dispersive solvent consumption. Analytical signals were obtained without back-extraction from the ZnO-NF phase prior to CV-AFS determination. Some essential parameters of the ZnO-NF VA-LLME and cold vapor generation such as composition and volume of the nanofluid, vortexing time, pH of the sample solution, amount of the chelating agent, ionic strength and matrix interferences have been studied. Under optimal conditions, efficient extraction of 1ng/mL of Hg(2+) in 10mL of sample solution was achieved using 50μL of ZnO-NF. The enrichment factor before dilution, detection limits and limits of quantification of the method were about 190, 0.019 and 0.064ng/mL, respectively. The intra and inter days relative standard deviations (n=8) were found to be 4.6% and 7.8%, respectively, at 1ng/mL spiking level. The accuracy of the current method was also evaluated by the analysis of certified reference materials, and the measured Hg(2+) concentration of GBW08603 (9.6ng/mL) and GBW(E)080392 (8.9ng/mL) agreed well with their certified value (10ng/mL). The method was applied to the analysis of Hg(2+) in effluent, influent, lake and river water samples, with recoveries in the range of 79.8-92.8% and 83.6-106.1% at 1ng/mL and 5ng/mL spiking levels, respectively. Overall, ZnO-NF VA-LLME is fast, simple, cost-effective and environmentally friendly and it can be employed for efficient enrichment of the analyte from various water samples.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  CV-AFS; Environmental waters; Inorganic mercury; LLME; Nanofuid

Mesh:

Substances:

Year:  2015        PMID: 26717850     DOI: 10.1016/j.talanta.2015.12.004

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Modification of a steel fiber with a graphene based bucky gel for headspace solid-phase microextraction of volatile aromatic hydrocarbons prior to their quantification by GC.

Authors:  Seyedeh Mahboobeh Yousefi; Farzaneh Shemirani; Sohrab Ali Ghorbanian
Journal:  Mikrochim Acta       Date:  2018-10-18       Impact factor: 5.833

2.  Surface-Active Ionic Liquid-Assisted Cloud Point Extraction for Pre-Concentration and Determination of Cobalt Ions in Pharmaceutical Preparations.

Authors:  Farzad Bamdad; Zahra Habibi
Journal:  Iran J Pharm Res       Date:  2022-05-17       Impact factor: 1.962

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.