Gastrografin as an alternative booster to sodium phosphate in colon capsule endoscopy: safety and efficacy pilot study.

Kazutomo Togashi1, Tomoki Fujita2, Kenichi Utano1, Eriko Waga2, Shinichi Katsuki2, Noriyuki Isohata1, Shungo Endo1, Alan K Lefor3.   

Abstract

BACKGROUND AND STUDY AIMS: Sodium phosphate is a key component of bowel preparation regimen for colon capsule endoscopy (CCE), but may cause serious complications. The aim of this study is to evaluate the use of Gastrografin, substituted for sodium phosphate, in CCE bowel preparation. PATIENTS AND METHODS: In total, 29 patients (median age 64 years; 23 females) underwent CCE, covered by the national health insurance system of Japan. All had a history of laparotomy and/or previously incomplete colonoscopy. On the day before examination, patients ingested 1 L of polyethylene glycol + ascorbic acid with 0.5 L of water in the evening, and again the same laxative on the morning of examination. After capsule ingestion, 50 mL of Gastrografin diluted with 0.9 L of magnesium citrate was administered, and then repeated after 1 hour.
RESULTS: The capsule excretion rate was 97 % (28/29). The median colon transit time was 2 hours 45 minutes and rapid transit (< 40 minutes) through the colon occurred in one patient (3.4 %). Bowel cleansing level was adequate in 90 % of patients. The polyp (≥ 6 mm) detection rate was 52 %. Diluted Gastrografin was well tolerated by patients. No adverse events occurred.
CONCLUSION: Gastrografin can be an alternative to sodium phosphate in CCE bowel preparation regimen.

Entities:  

Year:  2015        PMID: 26716132      PMCID: PMC4683135          DOI: 10.1055/s-0034-1393075

Source DB:  PubMed          Journal:  Endosc Int Open        ISSN: 2196-9736


Introduction

Sodium phosphate (NaP) is a key component of the standard bowel preparation regimen for colon capsule endoscopy (CCE, PillCom® COLON2 Capsule Endoscopy: Medtronic, Minneapolis, MN, USA), particularly to cause excretion of the capsule endoscope while the battery is still functioning. Previous reports have demonstrated that other laxatives including polyethylene glycol and magnesium citrate were not effective for excreting the capsule endoscope 1 2 3. However, the use of NaP is limited due to the possibility of causing severe adverse events, e. g. acute phosphate nephropathy, acute renal failure, hypertension, or mineral imbalance 4 5. The U.S. Food and Drug Administration issued a warning to restrict its purchase without a prescription in 2008. In Japan, administration of NaP for hypertensive patients 64 years or older has been contraindicated since February 2012. Therefore, an alternative to NaP is needed to perform CCE safely with a high completion rate. According to the latest report investigating the performance of CCE compared with CT colonography 6, Gastrografin (the water-soluble iodinated radiopaque oral contrast medium) was first used for the CCE regimen, because Gastrografin is generally used as part of the CT colonography regimen for “fecal tagging” 7. In our experience, a CCE regimen using Gastrografin without NaP, achieved a very high capsule excretion rate. The gastrointestinal transit time as well as the colon transit time with this bowel preparation regimen were comparable to that of CCE regimens using a NaP booster. In this paper, we report the results of a pilot study using Gastrografin as a booster in the bowel preparation regimen for CCE.

Patients and methods

From June 2014 to November 2014, 29 patients in two tertiary care hospitals (Aizu Medical Center and Otaru Ekiseikai General Hospital) underwent CCE, covered by the national health insurance system of Japan. To be eligible for insurance payment for colon capsule endoscopy, the patient must meet standardized indications for colon screening as well as one of the following conditions including: a previously incomplete colonoscopy, a previous laparotomy, or being unable to undergo colonoscopy due to some organic abnormality. Patient demographic data is shown in Table 1. The median age was 64 years and eight patients were older than 75 years. Most patients (79 %) were female. All had a history of laparotomy and/or previously incomplete colonoscopy. Patients with a history of bowel resection were not included. Sixteen patients (55 %) underwent the procedure to evaluate a positive fecal immunochemical test.

Patient demographic data.

All patients, n (%)29 (100)
Age, yearsMean64.1
Median64
Range42 – 91
Gender, n (%)Female23 (79)
Male 6 (21)
Previous laparotomy, n (%)Yes19 (66)
Previous incomplete colonoscopy, n (%)Yes16 (55)
Indication for colonoscopy, n (%)Positive fecal immunochemical test16 (55)
Post-polypectomy 6 (21)
Change in bowel habits 4 (14)
Hematochezia 2 (7)
Anemia 1 (3)
Details of the CCE regimen are shown in Table 2. Bowel preparation started from breakfast on the day before examination. Patients had low residue meals at breakfast and lunch, and drank 1 L of polyethylene glycol (PEG) plus ascorbic acid with 0.5 L of water in the evening, and 10 mL of sodium picosulfate hydrate at bedtime. On the morning of the examination, patients again drank 1 L of PEG plus ascorbic acid with 0.5 L of water. After capsule ingestion, 50 mL of Gastrografin diluted with 0.9 L of magnesium citrate was administered to facilitate capsule excretion. Gastrografin with magnesium citrate was given again after 1 hour. If the capsule was not expelled within 4 hours of ingestion, 50 mL of Gastrografin with water (by mouth) and/or a bisacodyl suppository were added. The capsule excretion rate within the duration of battery life, gastrointestinal transit time, colon transit time, bowel cleansing, and yield of colon polyp identification were measured. Bowel cleansing was rated on a four-point scale (poor, fair, good, excellent) to describe the preparation of the colon at the time of the capsule endoscopy 8 9.

Bowel preparation regimen.

DayHourAction
Day before examAll dayLow-residue diet
EveningMoviprep 1 L + water 0.5 L
BedtimeLaxoberon 10 mL + water 0.2 L
Day of exam07:00Moviprep 1 L + water 0.5 L
09:30Capsule ingestion
 + 0.1 % domperidone syrup 30 mL (30 mg)
 + mosapride 10 mg
10:30Magcorol P isotonic solution 0.9 L
 + mosapride 10 mg
 + Gastrografin 50 mL
11:30Magcorol P isotonic solution 0.9 L
 + Gastrografin 50 mL
12:30Suppository (bisacodyl 10 mg)

Moviprep: polyethylene glycol + ascorbic acid; Laxoberon: sodium picosulfate hydrate; Magcorol P: magnesium citrate; Gastrografin: diatrizoate meglumine and diatrizoate sodium.

Moviprep: polyethylene glycol + ascorbic acid; Laxoberon: sodium picosulfate hydrate; Magcorol P: magnesium citrate; Gastrografin: diatrizoate meglumine and diatrizoate sodium.

Results

The capsule excretion rate was 97 % (28 /29). The one patient who did not expel the capsule within the duration of battery life was a 51-year-old man with severe diverticular disease of the sigmoid colon. Gastrointestinal transit time, colon transit time, bowel cleansing, and yield of colon polyps are shown in Table 3. Median colon transit time was 165 minutes and rapid transit ( < 40 minutes) through the colon occurred in one patient (3.4 %, 1/29). Bowel cleansing was adequate (excellent/good) in 90 % of patients. The polyp (≥ 6 mm) detection rate was 52 %. All patients followed our regimen and diluted Gastrografin was well tolerated by all of them. No adverse events occurred in this pilot study.

Patient outcomes.

Capsule excretion rate within the life of the battery, n (%)28 (97)
Gastrointestinal transit time, minMedian281.5
Range105 – 641
Colon transit time, minMedian165
Range25 – 565
Bowel cleansing, n (%)Excellent11 (38)
Good15 (52)
Fair3 (10)
Poor0 (0)
Polyp yield, n (%)None1 14 (48)
6 – 10 mm7 (24)
 ≥ 11 mm8 (28)

Includes polyps ≤ 5 mm.

Includes polyps ≤ 5 mm.

Discussion

In our CCE regimen without NaP, but using Gastrografin instead, the capsule excretion rate, gastrointestinal transit time, colon transit time, and bowel cleansing were equivalent to previous reports using NaP as a booster 6 10 11. Bowel cleansing was adequate in most patients, allowing a high polyp detection rate. These results indicate that Gastrografin is an alternative to NaP for CCE bowel preparation. Gastrografin, known generically as diatrizoate meglumine and diatrizoate sodium, was developed as a water-soluble iodinated radiopaque oral contrast medium in 1960, and is still used in radiographic examinations because of its unique characteristics. According to the manufacturer’s information [http://www.bayerhealthcare.at/de/produkte/g-l/gastrografin/index.php], the osmolality of Gastrografin is nine times as high as that of blood plasma although the osmolality of NaP could be more than 30 times higher in preliminary calculations. Therefore, Gastrografin can work as a hyperosmotic laxative. While NaP is likely to increase the serum level of inorganic phosphate due to high phosphate level, most of the Gastrografin is not absorbed from the intestinal tract into the circulation. Overall, ≤ 2 % of Gastrografin is excreted into the urine without being metabolized. These characteristics suggest that an electrolyte imbalance is less frequently caused by oral/anal administration of Gastrografin. Gastrografin is a safe hyperosmotic laxative, and is a booster suitable for patients at increased risk. In this pilot study, including eight patients older than 75 years, no adverse events occurred. The latest clinical trial 12 conducted in the United States used a sulfate solution (SUPREP; Braintree Laboratories) as a booster for colon capsule endoscopy. In this large clinical trial, the median colon transit time was 75 minutes and occasionally the capsule passed through the colon within 40 minutes. Subsequently, approximately 10 % (77/772) of subjects were excluded from the final analysis, based on the combination of poor preparation and rapid transit after enrollment. Because the sulfate solution is poorly absorbed, the osmotic effect of unabsorbed sulfate anions and associated cations causes water to be retained within the intestine, thus expelling the capsule in a short time. In the present study using Gastrografin as a booster, the median colon transit time (165 minutes) was longer than that in the clinical trial using a sulfate solution. Gastrografin booster may provide sufficient observation time for the colon. Indeed, the polyp (≥ 6 mm) detection rate was comparably high (52 %) in the present study. There are acknowledged limitations to this study. This is a pilot study before a clinical trial, which limits the generalizability of the results. In addition, the present study was conducted in highly selected patients with a history of laparotomy and/or previously incomplete colonoscopy, possibly limiting the ability to generalize these results to other patient groups. We acknowledge that the polyp detection with CCE has not been verified by follow-up colonoscopy, which could alter the results of the yield of colon polyps. Despite these limitations, we believe that consideration of Gastrografin as an alternative booster is of interest. In conclusion, the use of Gastrografin in the CCE bowel preparation regimen is promising. Other modifications to the protocol may influence the high capsule excretion rate. A clinical trial is warranted to compare regimens with and without Gastrografin.
  12 in total

1.  Accuracy of capsule colonoscopy and computed tomographic colonography in individuals with positive results from the fecal occult blood test.

Authors:  Emanuele Rondonotti; Claudia Borghi; Giovanna Mandelli; Franco Radaelli; Silvia Paggi; Arnaldo Amato; Gianni Imperiali; Natalia Terreni; Nicoletta Lenoci; Vittorio Terruzzi; Alessandra Baccarin; Alberto Martegani; Giancarlo Spinzi
Journal:  Clin Gastroenterol Hepatol       Date:  2014-01-05       Impact factor: 11.382

2.  Accuracy of capsule colonoscopy in detecting colorectal polyps in a screening population.

Authors:  Douglas K Rex; Samuel N Adler; James Aisenberg; Wilmot C Burch; Cristina Carretero; Yehuda Chowers; Steven A Fein; Steven E Fern; Ignacio Fernandez-Urien Sainz; Alexander Fich; Eyal Gal; John C Horlander; Kim L Isaacs; Revital Kariv; Adi Lahat; Wai-Keung Leung; Pramod R Malik; Doug Morgan; Neofytos Papageorgiou; David P Romeo; Smita S Shah; Matti Waterman
Journal:  Gastroenterology       Date:  2015-01-22       Impact factor: 22.682

3.  PillCam colon capsule endoscopy compared with colonoscopy for colorectal tumor diagnosis: a prospective pilot study.

Authors:  N Schoofs; J Devière; A Van Gossum
Journal:  Endoscopy       Date:  2006-10       Impact factor: 10.093

4.  Evaluation of the PillCam Colon capsule in the detection of colonic pathology: results of the first multicenter, prospective, comparative study.

Authors:  R Eliakim; Z Fireman; I M Gralnek; K Yassin; M Waterman; Y Kopelman; J Lachter; B Koslowsky; S N Adler
Journal:  Endoscopy       Date:  2006-10       Impact factor: 10.093

Review 5.  Bowel preparation regimens for colon capsule endoscopy: a review.

Authors:  Shashideep Singhal; Sofia Nigar; Vani Paleti; Devin Lane; Sushil Duddempudi
Journal:  Therap Adv Gastroenterol       Date:  2014-05       Impact factor: 4.409

6.  PillCam colon capsule endoscopy: a prospective, randomized trial comparing two regimens of preparation.

Authors:  Cristiano Spada; Maria Elena Riccioni; Cesare Hassan; Lucio Petruzziello; Paola Cesaro; Guido Costamagna
Journal:  J Clin Gastroenterol       Date:  2011-02       Impact factor: 3.062

7.  Colon capsule versus CT colonography in patients with incomplete colonoscopy: a prospective, comparative trial.

Authors:  Cristiano Spada; Cesare Hassan; Brunella Barbaro; Franco Iafrate; Paola Cesaro; Lucio Petruzziello; Leonardo Minelli Grazioli; Carlo Senore; Gabriella Brizi; Isabella Costamagna; Giuseppe Alvaro; Marcella Iannitti; Marco Salsano; Maria Ciolina; Andrea Laghi; Lorenzo Bonomo; Guido Costamagna
Journal:  Gut       Date:  2014-06-24       Impact factor: 23.059

8.  Accuracy of CT colonography for detection of large adenomas and cancers.

Authors:  C Daniel Johnson; Mei-Hsiu Chen; Alicia Y Toledano; Jay P Heiken; Abraham Dachman; Mark D Kuo; Christine O Menias; Betina Siewert; Jugesh I Cheema; Richard G Obregon; Jeff L Fidler; Peter Zimmerman; Karen M Horton; Kevin Coakley; Revathy B Iyer; Amy K Hara; Robert A Halvorsen; Giovanna Casola; Judy Yee; Benjamin A Herman; Lawrence J Burgart; Paul J Limburg
Journal:  N Engl J Med       Date:  2008-09-18       Impact factor: 91.245

9.  Renal failure due to acute nephrocalcinosis following oral sodium phosphate bowel cleansing.

Authors:  Glen S Markowitz; Samih H Nasr; Philip Klein; Herman Anderson; Jay I Stack; Lloyd Alterman; Barbara Price; Jai Radhakrishnan; Vivette D D'Agati
Journal:  Hum Pathol       Date:  2004-06       Impact factor: 3.466

10.  Is PillCam COLON capsule endoscopy ready for colorectal cancer screening? A prospective feasibility study in a community gastroenterology practice.

Authors:  Andreas Sieg; Kilian Friedrich; Ulla Sieg
Journal:  Am J Gastroenterol       Date:  2009-02-24       Impact factor: 10.864

View more
  10 in total

Review 1.  Colon capsule endoscopy: toward the future.

Authors:  Naoki Muguruma; Kumiko Tanaka; Satoshi Teramae; Tetsuji Takayama
Journal:  Clin J Gastroenterol       Date:  2017-01-13

2.  Multicenter, randomized study to optimize bowel preparation for colon capsule endoscopy.

Authors:  David Kastenberg; Wilmot C Burch; David P Romeo; Pankaj K Kashyap; David C Pound; Neophytos Papageorgiou; Ignacio Fernández-Urien Sainz; Carly E Sokach; Douglas K Rex
Journal:  World J Gastroenterol       Date:  2017-12-28       Impact factor: 5.742

Review 3.  Review: capsule colonoscopy-a concise clinical overview of current status.

Authors:  Diana E Yung; Emanuele Rondonotti; Anastasios Koulaouzidis
Journal:  Ann Transl Med       Date:  2016-10

4.  Predictors of Gastrointestinal Transit Times in Colon Capsule Endoscopy.

Authors:  Sarah Moen; Fanny E R Vuik; Trudy Voortman; Ernst J Kuipers; Manon C W Spaander
Journal:  Clin Transl Gastroenterol       Date:  2022-05-18       Impact factor: 4.396

Review 5.  Contraindications for video capsule endoscopy.

Authors:  Dirk Bandorski; Niehls Kurniawan; Peter Baltes; Reinhard Hoeltgen; Matthias Hecker; Dominik Stunder; Martin Keuchel
Journal:  World J Gastroenterol       Date:  2016-12-07       Impact factor: 5.742

6.  Can coffee or chewing gum decrease transit times in Colon capsule endoscopy? A randomized controlled trial.

Authors:  Maria Magdalena Buijs; Morten Kobaek-Larsen; Lasse Kaalby; Gunnar Baatrup
Journal:  BMC Gastroenterol       Date:  2018-06-25       Impact factor: 3.067

7.  Booster medication to achieve capsule excretion in colon capsule endoscopy: a randomized controlled trial of three regimens.

Authors:  Rasmus Kroijer; Anne-Kirstine Dyrvig; Morten Kobaek-Larsen; Jens Overgaard Støvring; Niels Qvist; Gunnar Baatrup
Journal:  Endosc Int Open       Date:  2018-11-07

8.  Colon capsule endoscopy versus CT colonography in FIT-positive colorectal cancer screening subjects: a prospective randomised trial-the VICOCA study.

Authors:  Begoña González-Suárez; Mario Pagés; Isis Karina Araujo; Cristina Romero; Cristina Rodríguez de Miguel; Juan Ramón Ayuso; Àngels Pozo; Maria Vila-Casadesús; Anna Serradesanferm; Àngels Ginès; Glòria Fernández-Esparrach; Maria Pellisé; María López-Cerón; David Flores; Henry Córdova; Oriol Sendino; Jaume Grau; Josep Llach; Miquel Serra-Burriel; Andrés Cárdenas; Francesc Balaguer; Antoni Castells
Journal:  BMC Med       Date:  2020-09-18       Impact factor: 8.775

9.  Feasibility of patency capsule and colon capsule endoscopy in patients with suspected gastrointestinal stenosis: a prospective study.

Authors:  Hiroyuki Otsuka; Masanao Nakamura; Takeshi Yamamura; Keiko Maeda; Tsunaki Sawada; Yasuyuki Mizutani; Eri Ishikawa; Takuya Ishikawa; Naomi Kakushima; Kazuhiro Furukawa; Eizaburo Ohno; Hiroki Kawashima; Takashi Honda; Masatoshi Ishigami; Mitsuhiro Fujishiro
Journal:  Nagoya J Med Sci       Date:  2021-08       Impact factor: 1.131

Review 10.  Review: Colon Capsule Endoscopy in Inflammatory Bowel Disease.

Authors:  Writaja Halder; Faidon-Marios Laskaratos; Hanan El-Mileik; Sergio Coda; Stevan Fox; Saswata Banerjee; Owen Epstein
Journal:  Diagnostics (Basel)       Date:  2022-01-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.