Literature DB >> 26715658

Comparison of Outside Versus Inside Brachial Plexus Sheath Injection for Ultrasound-Guided Interscalene Nerve Blocks.

Joni Maga1, Andres Missair2, Alex Visan1, Lee Kaplan1, Juan F Gutierrez1, Annika R Jain1, Ralf E Gebhard1.   

Abstract

OBJECTIVES: Ultrasound-guided interscalene brachial plexus blocks are commonly used to provide anesthesia for the shoulder and proximal upper extremity. Some reviews identify a sheath that envelops the brachial plexus as a potential tissue plane target, and current editorials in the literature highlight the need to establish precise and reproducible injection targets under ultrasound guidance. We hypothesize that an injection of a local anesthetic inside the brachial plexus sheath during ultrasound-guided interscalene nerve blocks will result in enhanced procedure success and provide a consistent tissue plane target for this approach with a reproducible and characteristic local anesthetic spread pattern.
METHODS: Sixty patients scheduled for shoulder surgery with a preoperative interscalene block for postoperative pain management were enrolled in this prospective randomized observer-blinded study. Each patient was randomly assigned to receive a single-shot interscalene block either inside or outside the brachial plexus sheath.
RESULTS: The rate of complete motor and sensory blocks of the axillary nerve territory 10 minutes after local anesthetic injection for the inside group was 70% versus 37% for the outside group (P < .05). At all measurement intervals beyond 10 minutes, however, neither group showed a statistically significant difference in complete sensory blockade. The incidence rates of transient paresthesia during needle passage were 6.7% for the outside group and 96.7% for the inside group (P < .05).
CONCLUSIONS: Except for faster onset, this prospective randomized trial did not find any advantages to performing an interscalene block inside the brachial plexus sheath. There was a higher incidence of transient paresthesia when injections were performed inside compared to outside the sheath.
© 2016 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  brachial plexus; interscalene block; neurosonology; regional anesthesia

Mesh:

Substances:

Year:  2015        PMID: 26715658     DOI: 10.7863/ultra.15.01059

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  1 in total

1.  Extraplexus versus intraplexus ultrasound-guided interscalene brachial plexus block for ambulatory arthroscopic shoulder surgery: A randomized controlled trial.

Authors:  Monica W Harbell; Kerstin Kolodzie; Matthias Behrends; C Benjamin Ma; Sakura Kinjo; Edward Yap; Matthias R Braehler; Pedram Aleshi
Journal:  PLoS One       Date:  2021-02-18       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.