S Yamamoto1, J Bergsland, S M Michalek, M Carroll, J M Gona, D Balu, E A Carr.
Abstract
To study the scintigraphic detectability of cardiac rejection, we performed 135 planar myocardial scans ([99mTc]pyrophosphate, 85; 201Tl, 36; 67Ga, 14) together with endomyocardial biopsies in ten patients for a (mean) 17-mo postoperative period. Specificity of each agent exceeded 89%. Technetium-99m pyrophosphate showed results that significantly correlated with the severity of rejection (p = 0.03), as shown by biopsy, but neither 201Tl nor 67Ga did so (p = 0.63 and 0.81, respectively). Technetium-99m pyrophosphate showed better diagnostic accuracy (85%) than 201Tl (69%) and 67Ga (64%). Technetium-99m pyrophosphate also showed higher negative predictive value (91%) than thallium (76%) and gallium (69%). Thus, a normal 99mTc pyrophosphate scan was usually associated with absence of cardiac rejection. However, all three agents showed unacceptably poor sensitivity (0% to 30%) and thus were not useful as a screening test for cardiac rejection, even when the same agent was used serially in imaging a given patient.Entities:
Mesh:
Substances:
Year: 1989 PMID: 2671299
Source DB: PubMed Journal: J Nucl Med ISSN: 0161-5505 Impact factor: 10.057