Literature DB >> 26710344

An integrated direct loop-mediated isothermal amplification microdevice incorporated with an immunochromatographic strip for bacteria detection in human whole blood and milk without a sample preparation step.

Dohwan Lee1, Yong Tae Kim2, Jee Won Lee2, Do Hyun Kim2, Tae Seok Seo3.   

Abstract

We have developed an integrated direct loop-mediated isothermal amplification (Direct LAMP) microdevice incorporated with an immunochromatographic strip (ICS) to identify bacteria contaminated in real samples. The Direct LAMP is a novel isothermal DNA amplification technique which does not require thermal cycling steps as well as any sample preparation steps such as cell lysis and DNA extraction for amplifying specific target genes. In addition, the resultant amplicons were colorimetrically detected on the ICS, thereby enabling the entire genetic analysis process to be simplified. The two functional units (Direct LAMP and ICS) were integrated on a single device without use of the tedious and complicated microvalve and tubing systems. The utilization of a slidable plate allows us to manipulate the fluidic control in the microchannels manually and the sequential operation of the Direct LAMP and ICS detection could be performed by switching the slidable plate to each functional unit. Thus, the combination of the direct isothermal amplification without any sample preparation and thermal cycling steps, the ICS based amplicon detection by naked eyes, and the slidable plate to eliminate the microvalves in the integrated microdevice would be an ideal platform for point-of-care DNA diaganotics. On the integrated Direct LAMP-ICS microdevice, we could analyze Staphylococcus aureus (S. aureus) and Escherichia coli O157:H7 (E. coli O157:H7) contaminated in human whole blood or milk at a single-cell level within 1h.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Colorimetric detection; Direct loop-mediated isothermal amplification; Integrated microdevice; No sample pretreatment; Valveless

Mesh:

Year:  2015        PMID: 26710344     DOI: 10.1016/j.bios.2015.12.044

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  10 in total

Review 1.  Signal amplification in immunoassays by using noble metal nanoparticles: a review.

Authors:  Hualin Yang; Wentao Xu; Yu Zhou
Journal:  Mikrochim Acta       Date:  2019-11-30       Impact factor: 5.833

2.  Development of a filtration-based LAMP-LFA method as sensitive and rapid detection of E. coli O157:H7.

Authors:  Jin-Hee Kim; Se-Wook Oh
Journal:  J Food Sci Technol       Date:  2019-04-01       Impact factor: 2.701

3.  Paper-based RNA detection and multiplexed analysis for Ebola virus diagnostics.

Authors:  Laura Magro; Béatrice Jacquelin; Camille Escadafal; Pierre Garneret; Aurélia Kwasiborski; Jean-Claude Manuguerra; Fabrice Monti; Anavaj Sakuntabhai; Jessica Vanhomwegen; Pierre Lafaye; Patrick Tabeling
Journal:  Sci Rep       Date:  2017-05-02       Impact factor: 4.379

Review 4.  Towards Multiplex Molecular Diagnosis-A Review of Microfluidic Genomics Technologies.

Authors:  Ismail Hussain Kamal Basha; Eric Tatt Wei Ho; Caffiyar Mohamed Yousuff; Nor Hisham Bin Hamid
Journal:  Micromachines (Basel)       Date:  2017-08-30       Impact factor: 2.891

5.  A Disposable and Multi-Chamber Film-Based PCR Chip for Detection of Foodborne Pathogen.

Authors:  Nam Ho Bae; Sun Young Lim; Younseong Song; Soon Woo Jeong; Seol Yi Shin; Yong Tae Kim; Tae Jae Lee; Kyoung G Lee; Seok Jae Lee; Yong-Jun Oh; Yoo Min Park
Journal:  Sensors (Basel)       Date:  2018-09-19       Impact factor: 3.576

6.  Portable and Battery-Powered PCR Device for DNA Amplification and Fluorescence Detection.

Authors:  Junyao Jie; Shiming Hu; Wenwen Liu; Qingquan Wei; Yizheng Huang; Xinxin Yuan; Lufeng Ren; Manqing Tan; Yude Yu
Journal:  Sensors (Basel)       Date:  2020-05-05       Impact factor: 3.576

7.  Development of Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Rapid and On-Site Detection of Avian Influenza Virus.

Authors:  Mohsen Golabi; Marion Flodrops; Beatrice Grasland; Aaydha C Vinayaka; Than Linh Quyen; Trieu Nguyen; Dang Duong Bang; Anders Wolff
Journal:  Front Cell Infect Microbiol       Date:  2021-04-19       Impact factor: 5.293

Review 8.  The Revolution of Lateral Flow Assay in the Field of AMR Detection.

Authors:  Hervé Boutal; Christian Moguet; Lilas Pommiès; Stéphanie Simon; Thierry Naas; Hervé Volland
Journal:  Diagnostics (Basel)       Date:  2022-07-19

9.  Rapid, Portable, Multiplexed Detection of Bacterial Pathogens Directly from Clinical Sample Matrices.

Authors:  Christopher R Phaneuf; Betty Mangadu; Matthew E Piccini; Anup K Singh; Chung-Yan Koh
Journal:  Biosensors (Basel)       Date:  2016-09-23

10.  Rapid detection of cytochrome cd1-containing nitrite reductase encoding gene nirS of denitrifying bacteria with loop-mediated isothermal amplification assay.

Authors:  Xuzhi Zhang; Qianqian Yang; Qingli Zhang; Xiaoyu Jiang; Xiaochun Wang; Yang Li; Jun Zhao; Keming Qu
Journal:  Sci Rep       Date:  2020-10-05       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.