Literature DB >> 26708861

Effectiveness of an advanced hemostatic pad combined with harmonic scalpel in thyroid surgery. A prospective study.

Roberto Ruggiero1, Ludovico Docimo2, Salvatore Tolone2, Maurizio De Palma3, Mario Musella4, Angela Pezzolla5, Adelmo Gubitosi2, Domenico Parmeggiani2, Raffaele Pirozzi2, Simona Gili2, Simona Parisi2, Antonio D'Alessandro2, Giovanni Docimo2.   

Abstract

INTRODUCTION: Hemostasis during thyroidectomy is essential; however the most efficient and cost-effective way to achieve this is unclear. The aim of this study was to evaluate the outcome of total thyroidectomy (TT) performed with the combination of harmonic scalpel (HS) and an advanced hemostatic pad (Hemopatch).
METHODS: Patient undergone TT were divided into two groups: HS + hemopatch and HS + traditional hemostasis groups. The primary endpoint was 24-h drain output and blood-loss requiring reintervention. Secondary endpoints included surgery duration, postsurgical complications and hypocalcemia rates.
RESULTS: Between September 2014 and March 2015, 60 patients were enrolled (30 to Hs + Hemopatch, 30 to Hs and standard hemostasis); 71.4% female; mean age 48.5 years. The 24-h drain output was lower in the HS + hemopatch group compared with standard TT. HS and hemopatch also had a shorter mean surgery time (p < 0.0001) vs standard TT.
CONCLUSION: combination of hemopatch plus HS is effective and safe for TT with a complementary hemostatic approach.
Copyright © 2015. Published by Elsevier Ltd.

Entities:  

Keywords:  Harmonic scalpel; Hemopatch; Total thyroidectomy

Mesh:

Year:  2015        PMID: 26708861     DOI: 10.1016/j.ijsu.2015.12.044

Source DB:  PubMed          Journal:  Int J Surg        ISSN: 1743-9159            Impact factor:   6.071


  3 in total

1.  Risk factors for postoperative hypocalcemia.

Authors:  Giovanni Docimo; Roberto Ruggiero; Giuseppina Casalino; Gianmattia Del Genio; Ludovico Docimo; Salvatore Tolone
Journal:  Updates Surg       Date:  2017-04-25

2.  Case Report of a Novel Technique for Repair of the Vertebral Artery During Cranial Surgery.

Authors:  Manjunath Prasad; Nitin Mukerji
Journal:  Neurol Ther       Date:  2019-07-05

3.  Hemopatch® is effective and safe to use: real-world data from a prospective European registry study.

Authors:  Carlo Lombardo; Santiago Lopez-Ben; Ugo Boggi; Piotr Gutowski; Tomas Hrbac; Lukas Krska; Javier Marquez-Rivas; Domenico Russello; Elisa York; Mario Zacharias
Journal:  Updates Surg       Date:  2022-08-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.