Literature DB >> 26706971

Geostatistics - a tool applied to the distribution of Legionella pneumophila in a hospital water system.

Pasqualina Laganà1, Umberto Moscato2, Andrea Poscia2, Daniele Ignazio La Milia2, Stefania Boccia2, Emanuela Avventuroso1, Santi Delia1.   

Abstract

INTRODUCTION: Legionnaires' disease is normally acquired by inhalation of legionellae from a contaminated environmental source. Water systems of large buildings, such as hospitals, are often contaminated with legionellae and therefore represent a potential risk for the hospital population. The aim of this study was to evaluate the potential contamination of Legionella pneumophila (LP) in a large hospital in Italy through georeferential statistical analysis to assess the possible sources of dispersion and, consequently, the risk of exposure for both health care staff and patients. MATERIALS AND
METHOD: LP serogroups 1 and 2-14 distribution was considered in the wards housed on two consecutive floors of the hospital building. On the basis of information provided by 53 bacteriological analysis, a 'random' grid of points was chosen and spatial geostatistics or FAIk Kriging was applied and compared with the results of classical statistical analysis.
RESULTS: Over 50% of the examined samples were positive for Legionella pneumophila. LP 1 was isolated in 69% of samples from the ground floor and in 60% of sample from the first floor; LP 2-14 in 36% of sample from the ground floor and 24% from the first. The iso-estimation maps show clearly the most contaminated pipe and the difference in the diffusion of the different L. pneumophila serogroups.
CONCLUSION: Experimental work has demonstrated that geostatistical methods applied to the microbiological analysis of water matrices allows a better modeling of the phenomenon under study, a greater potential for risk management and a greater choice of methods of prevention and environmental recovery to be put in place with respect to the classical statistical analysis.

Entities:  

Mesh:

Year:  2015        PMID: 26706971     DOI: 10.5604/12321966.1185769

Source DB:  PubMed          Journal:  Ann Agric Environ Med        ISSN: 1232-1966            Impact factor:   1.447


  3 in total

1.  Environmental Surveillance of Legionellosis within an Italian University Hospital-Results of 15 Years of Analysis.

Authors:  Pasqualina Laganà; Alessio Facciolà; Roberta Palermo; Santi Delia
Journal:  Int J Environ Res Public Health       Date:  2019-03-28       Impact factor: 3.390

2.  The Impact of Storms on Legionella pneumophila in Cooling Tower Water, Implications for Human Health.

Authors:  Robin L Brigmon; Charles E Turick; Anna S Knox; Courtney E Burckhalter
Journal:  Front Microbiol       Date:  2020-12-10       Impact factor: 5.640

3.  Risk assessment of legionellosis in cardiology units.

Authors:  P Laganà; S Delia; E Avventuroso; M Casale; G Dattilo
Journal:  J Prev Med Hyg       Date:  2017-06