Catalina Palomo-Álvarez1, María C Puell2. 1. From the Applied Vision Research Group, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain. Electronic address: cpalomoa@ucm.es. 2. From the Applied Vision Research Group, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.
Abstract
PURPOSE: To examine the capacity of straylight and disk halo size to diagnose cataract. SETTING: Faculty of Optics and Optometry, Universidad Complutense de Madrid, Spain. DESIGN: Prospective study. METHODS: Straylight, disk halo radius, and high-contrast corrected distance visual acuity (CDVA) measurements were compared between patients with age-related cataract and age-matched normal-sighted control subjects by calculating the area under the curve (AUC) receiver operating characteristic. RESULTS: Measurements were made in 53 eyes of 53 patients with a mean age of 67.94 years ± 7.11 (SD) and 31 eyes of 31 controls with a mean age 66.06 ± 5.43 years. Significantly worse (P < .001) mean straylight (1.38 ± 0.24 log[s]), mean disk halo radius (2.40 ± 0.18 log minutes of arc [arcmin]), and mean CDVA (0.17 ± 0.11 logMAR) were recorded in the cataract group than in the control group (1.17 ± 0.11 log[s], 2.10 ± 0.16 log arcmin, and 0.08 ± 0.08 logMAR). Significant differences in AUCs were observed for disk halo radius (0.89 ± 0.04) versus straylight (0.77 ± 0.05) (P = .03) and disk halo radius versus CDVA (0.72 ± 0.05) (P = .001). The comparison of disk halo radius versus the discriminant function with input from CDVA and straylight (0.80 ± 0.05) was at the limit of significance only (0.091 ± 0.05, P = .051). CONCLUSION: Although all 3 variables discriminated well between normal eyes and eyes with cataract, the disk halo radius showed the best diagnostic capacity. FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.
PURPOSE: To examine the capacity of straylight and disk halo size to diagnose cataract. SETTING: Faculty of Optics and Optometry, Universidad Complutense de Madrid, Spain. DESIGN: Prospective study. METHODS: Straylight, disk halo radius, and high-contrast corrected distance visual acuity (CDVA) measurements were compared between patients with age-related cataract and age-matched normal-sighted control subjects by calculating the area under the curve (AUC) receiver operating characteristic. RESULTS: Measurements were made in 53 eyes of 53 patients with a mean age of 67.94 years ± 7.11 (SD) and 31 eyes of 31 controls with a mean age 66.06 ± 5.43 years. Significantly worse (P < .001) mean straylight (1.38 ± 0.24 log[s]), mean disk halo radius (2.40 ± 0.18 log minutes of arc [arcmin]), and mean CDVA (0.17 ± 0.11 logMAR) were recorded in the cataract group than in the control group (1.17 ± 0.11 log[s], 2.10 ± 0.16 log arcmin, and 0.08 ± 0.08 logMAR). Significant differences in AUCs were observed for disk halo radius (0.89 ± 0.04) versus straylight (0.77 ± 0.05) (P = .03) and disk halo radius versus CDVA (0.72 ± 0.05) (P = .001). The comparison of disk halo radius versus the discriminant function with input from CDVA and straylight (0.80 ± 0.05) was at the limit of significance only (0.091 ± 0.05, P = .051). CONCLUSION: Although all 3 variables discriminated well between normal eyes and eyes with cataract, the disk halo radius showed the best diagnostic capacity. FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.
Authors: Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero Journal: J Ophthalmol Date: 2018-06-27 Impact factor: 1.909