Literature DB >> 26702967

Comparison of two methods for detection of fecal indicator bacteria used in water quality monitoring of the Three Gorges Reservoir.

Zhaodan Wang1, Guosheng Xiao2, Nong Zhou3, Wenhua Qi3, Lin Han3, Yu Ruan3, Dongqin Guo3, Hong Zhou3.   

Abstract

Scientifically sound methods to rapidly measure fecal indicator bacteria are important to ensure safe water for drinking and recreational purposes. A total of 200 water samples obtained from the Three Gorges Reservoir during three successive one-year study periods (October 2009 to September 2012) were analyzed using multiple-tube fermentation (MTF) and most probable numbers combined with polymerase chain reaction (MPN-PCR). The MPN-PCR method was found to be significantly more sensitive than the MTF method for detecting Escherichia coli and Enterococcus spp., and of equal sensitivity for detecting total coliforms when all surface water samples were grouped together. The two analytical methods had a strong, significant relationship, but MPN-PCR took only 12-18hr, compared with the 3-8days needed using the MTF method. Bacterial concentrations varied per sampling site but were significantly lower in the mainstream of the Yangtze River than those in the backwater areas of tributaries. The water quality of 85.8% of water samples from the mainstream was suitable for use as a centralized potable water source, while the water quality of 52.5% of water samples from the backwater areas was unsuitable for recreational activities. Relationships between fecal indicator bacteria showed significant correlation (r=0.636-0.909, p<0.01, n=200), while a weak but significant correlation was found between fecal indicators and water turbidity, water temperature, daily inflow, and total dissolved solids (r=0.237-0.532, p<0.05, n=200). The study indicated that MPN-PCR is a rapid and easily performed deoxyribonucleic acid (DNA)-based method for quantitative detection of viable total coliforms, E. coli, and Enterococcus spp. in surface water.
Copyright © 2015. Published by Elsevier B.V.

Entities:  

Keywords:  Fecal indicator bacteria; MPN–PCR; Multiple-tube fermentation; Surface water; Three Gorges Reservoir

Mesh:

Year:  2015        PMID: 26702967     DOI: 10.1016/j.jes.2015.04.029

Source DB:  PubMed          Journal:  J Environ Sci (China)        ISSN: 1001-0742            Impact factor:   5.565


  1 in total

1.  Prevalence of coliform bacterial contamination in cat drinking water in households in Thailand.

Authors:  Suttiporn Srikullabutr; Panpicha Sattasathuchana; Anusak Kerdsin; Naris Thengchaisri
Journal:  Vet World       Date:  2021-03-22
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.